How to calculate stirrups cutting length in columns
Answer Posted / karunya31
1) let cover for column be 40mm (as u have not mentioned)
formula to determine cutting length of stirrup is given below
cutting length= (2A+2B)+(24D)
A=LONGER LENGTH OF COLUMN-2XCOVER=400-40X2=320MM
B=SHORTER LENGTH OF COLUMN-2XCOVER=250-40X2=170MM
D= DIAMETER OF STIRRUP BAR IN MM
therefore
cutting length=2X320+2X170 + 24X8 =1172MM=1.172 meter
2) given cover 25mm (as u have mentioned)
formula to determine cutting length of stirrup is given below
cutting length= (2A+2B)+(24D)
A=LONGER LENGTH OF BEAM-2XCOVER=400-25X2=350MM
B=SHORTER LENGTH OF BEAM-2XCOVER=200-25X2=150MM
D= DIAMETER OF STIRRUP BAR IN MM
therefore
cutting length=2X350+2X150 + 24X8 =1192MM=1.192 meter
NOTE SLAB COVER HAS NOTHING TO DO WITH CAL.OF STIRRUPS
3) ASSUME cover 30mm (as u have NOT mentioned)
formula to determine cutting length of stirrup is given below
cutting length= (2A+2B)+(24D)
A=LONGER LENGTH OF COLUMN/2 -COVER=400/2-30=170MM
B=SHORTER LENGTH OF COLUMN-2XCOVER=250-30X2=190MM
D= DIAMETER OF STIRRUP BAR IN MM
therefore
cutting length=2X170+2X190 + 24X8 =912MM=0.912 meter EACH
Generally term stirrups are used for lateral tie for beams while term ring is used for columns.calculation of length for stirrups & ring are same. Stirrups length depend upon size of column/beam,cover,dia of stirrup's bar.Nominal cover is measured from outer face of stirrups to concrete face.Although this cover at site is measured from outer face of main bar.If cover for beam is 25 mm then, for 90 degree hook for 600x400 mm column & 10 mm dia bar as per IS Code 2502 length will be=2[(600-2x25)+(400-2x25)]+20x10mm=2000...
If there are four bar of 20mm dia on 600 mm face then for central stirrup of this side will be=[600-25-25-(20/2)-(20/2)]/3=176.66 between centre of two bars of this face,now add (20/2)+(20/2) so that outer face to outer face of 20 dia bar=196.6say 197mm. same way other side of central stirrups are calculated & then add 20 times bar dia.Add 24 xdia of bar for 135 degree hook
In IS code formula=2(A+B)+20 x bar dia. A & B are internal distance between stirrup side.
| Is This Answer Correct ? | 9 Yes | 2 No |
Post New Answer View All Answers
In the roof of a pumping station explain briefly the components of a waterproofing system?
what is m30 in concrete tiles
what is the percentage of silt in black cotton soil.?
What are segregation and bleeding?
What is thumb rule for deep trench excavation
how to identify np3 pipe and np4 pipe
what post do you prefer to work in this company and why do you think you can serve better in such position?
what do you understand by M25 concrete
What are the common ways of demolition?
rcc floor to floor 4m. in column reinforcement where we provide lap in exact location.
if a pipe those configuration (ASTM c 76 class b 450mm dia 2500mm length) fixing for water course those lining of water is 7000 running meter. my question is that if 8 joints of pipe ls leakage and we have not permission to stop the water so which treatment we apply on joint in that in condition.
how i can calculate the actual nos & size of steel to make 1000sqft. x 3"thick slab
Suppose a new brick wall is being constructed,and the courses and not aligned horizontally,what negetives can it cause?
WET BULB TEMPERATURE AND DRY BULB TEMPERATURE?
Explain soil analysis?