in my company organisation in plan to take new PLC system
for replacing old relay system , for that what I/P needsd to
submit to the system house of PLC supplier?
Answer Posted / carl_ellis
in my company organisation in plan to take new PLC system
for replacing old relay system , for that what I/P needsd
to submit to the system house of PLC supplier?
An I/P is a current to pneumatic transducer, typically 4-
20mA to 3-15 psig (in North America)
It is used with modulating control valve assemblies that
have pneumatic (input) positioners or for modulating
control valve assemblies with pneumatic actuators that have
no positioner, but have an actuator and a spring sized for
direct pneumatic control from an I/P signal.
A PLC outputs only an electronic control signal, so an I/P
is needed for either of the types of modulating control
valves described above. So count the number of those
kinds of devices and you'll know how many I/Ps you need.
Carl Ellis
Measure First
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
If a control valve is hunting means means if we are giving 50% to the cv, the cv will open at 51% then slowly slwoly it will reaches 49% , so what to do for solve this problem. The cv is double acting and mounted for anti surge operation, it having 4 nos. volume booster, one sov, one positioner, etc..?
if in a level tx height is given, how u calculate the ranges of the tx?
basic connection and principle of axial shift sensor n differential sensors in tubine describes n draw......
POSSITIVE PULSE IS APPLIED TO AN INVERTER INPUT.THE TIME FROM THE LEADING EDGE OF THE INPUT TO THE LEADING EDGE OF THE OUTPUT IS 10 ns. THE TIME FROM THE TRAILING EDGE OF THE INPUT TO THE TRYLING EDGE OF THE OUTPUT IS 8 ns. WHAT ARE THE VALUES OF tPLH and tPHL?
any body please send me the old question papers of ongc test.
1.what is controller proportional gain 2.what is the controller intergral action time. 3.A proportional plus derivative controller that has a proportional band of 20% and a derivative action time of 0.1 minutes. Construct the shape of the output waveform for the triangular input if the input rises and falls at the rate of 4 units per minute.
State four different types of flow measurement, for gas flow measurement MMSCFD is the common unit expand the unit and specify significance of word S in the unit.
Can combine control system for Emergency control system (ESD)and Fire & Gas System ( F & G) is possble to built and offer to client? Can such system is as per Norms in India?
What is the constant voltage unit?
Whatis the reset ofset and control system in instrumentation
Hi my friends Is any one who can assist me in knowing the typical interview questions for system engineer at General Electric pty Ltd
components of control circuit belongs to control valve
Can anyone convert a 5/2 way or 3/2 way valve into an ISO valve?
what is use of communication wire in multipare cable(oil and gas field), why this communication wire not used in single pair cable?
What is PDS and PDMS ?