the resistance of wire having length X M is R OHEM if i
streched the wire to dubble length what will be the
resitance
Answer Posted / sasi karthick a
Not exactly, while streching the wire not only the length
but cross sectional area also changes. So it also depends
on both after streching.
Since R=(pl)/A.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
what is the basic need of domestic loads 1- voltage 2- current
What is Faraday's law
How many wall/floor flange will i use in bus duct system if we have in our design a 35th floor building.
How dia computation perfomed in cold rolling mills .
what is gas turbine intercooling ?
suri transmission
can any one tell me about the Extra low voltage systems?From where we give supply to these type of systems??
Write the force balance equation of ideal spring element.
What is the restart inhabit setting in ABB spam150c relay (Motor protection relay)
How PADO software increase the efficiency of power plant?
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
how does WTI work ?
Control wiring of a dol starter for forward and backward
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
in a solar power plant,we are going to step up the voltage 350V to 33kv, and to 132kv GSS. i want to ask that if it is possible that 315v/33kv is not possible because we also use 315v/11kv. or it should be 415v/33kv? is it effects generation or losses? the second question is-generation is depends on LV winding? or LV winding design for generation voltage?