What is the power ratio between power in Star and Delta
circuit?
Answer Posted / sasi karthick a
The power is depends on the resistance of the winding. Lets
Take "R"ohm resistance of winding and connect in star
configuration.
then transform it to delta. You will see the result. It
will "R/3". So low resistance, high current, power.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
why did youi choose this career?
i am completed my degree(B.E EEE) 2014 anychance to get electrical licence plz help me
why motor range is available 22kv,30kv,37kv,45kv and so on? why motor range is not available 21kv,24,25,26,27kv and so on?
Hi Friend I am used multimeter to measure the voltage between R Phase(SS1) to R Phase(SS2). In SS1 is connected with UPS loads. But I am getting voltage between these 2 R Phases. Please give some idea friend
How will calculate losses in an multi core Aluminium LT cable of different sizes & upto what length we can use a LT Cable ?
What is the formula of frequency ?
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
3 shows a 415 V, 3-phase generator supplying a 3-phase 415/110 V transformer. Draw the individual and combined impedance diagrams to a base of 10 kVA. Determine the system fault kVA and the fault currents at the 415 V and 110 V busbars for short circuit faults on the transformer input or output terminals. Work in p.u. values of impedances.
what are the effects when a salient pole alternator is run at high speed like 3000 r.p.m?
What is meant by celling voltage & current in excitor ?
what is the minimum voltage require to injure our body?
what are inductive and capacitive voltage transformers.what are their applications
Calculate torque developed by the 3-phase, 5 H.P., 4 pole induction motor runs at 1500 rpm A 23 N-m B 21 N-m C 10 N-m D 0 N-m
what is meant by k-rating in isolation transformer?what is k9, k14 stands for?
What the difference between ac and dc inductor an capacitor