Difference between ups

Answer Posted / mayank

1. UPS, standing for Uninterruptable Power Supply, is an
electric circuit (device) which instantly backs up power
supply for a gadget.On the other hand, inverter is circuitry
which converts AC to DC and stores in the battery.
2. Inverter converts DC power (stored in its battery) to
fulfill respective requirements of the devices.UPS does the
similar task of power supply and is quite similar to
inverter’s working in order to supply power.
3. Inverter has a wider range of input power as compared to UPS.
4. UPS circuitry is far more sophisticated than that of
inverters.

Is This Answer Correct ?    7 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

i have applied for the post of RRB section engineering chennai board please send me previou papers and solved answer. my mail id jagarapusrinivas@gmail.com

1488


If I want to connect a capacitor bank on the HT side of a 11kV/415V, 3 phase delta-star distribution transformer to supply Reactive power to it..what practical specifications of a Capacitor bank that can i've??please reply..

2044


why constant voltage transformer should be start without load? and if started then what will happen?

1618


What are approaches to tackle sedimentation problem of reservoir?

594


why the name trunking bus PT

2499






What is the earth treantment procedure?

1618


Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.

1103


I HAVE A INCOMING 100A MCCB TPN 25KA, CABLE LENGHT OF 80M 70MM CABLE SIZE FROM MAIN SUBBOARD TO NEW DB.BASE ON THE FAULT LEVEL SETTING OF 45KA.I WOULD LIKE TO FIND OUT 25KA ENOUGH KA. APPRECIATE IF SOMEBODY CAN ASSIST ME WITH FORMULA FOR THIS. FRM: JEFF

3524


how we decide scurt (disc) of insulator with respect to kv rating

2921


Why efficiency in thermal power plant is low?

654


How will polarity test of Dy5 Transformer ?

1702


what are the advantages and disadvantages of oil filled cables over XLPE cables

18048


what is value of Jin transformer

1646


how many types control panel of a 132/33 kv substation

2237


Logic using 1 kV or 1,1 kV grade in house wiring Low voltage cable. Explain/suggest? some use 1kV and some prefer 1.1kV grade insulation low voltage cable why??

1227