Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what are the types of starter ?

Answer Posted / shiva s siranji

Most Useges this belove list.
1) Direct on line (DOL) starter,
2) Star-Delta starter,
3) Auto transformer starter,
4) Steps starter,
5) Motor soft starter
6) three point starter
7) four point starter

Is This Answer Correct ?    14 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to select the proper VSD to operate high inertial load

1739


How to calculate VA rating for CT or PT or Control Transformer?

2855


ASTM D 3455 - Standard Test Methods for Compatibility of Construction Material with Electrical Insulating Oil of Petroleum Origin has been used for Testing Transformer Oils with a product placed in it. Aged Control Oil has a Power Factor of 0.032% at 100°C. Aged Oil with a Test component has a Power Factor of 0.093% at 100°. Is this increase acceptable? If not why? How much increase is acceptable?

2030


How to findout raw or ups power? its not indicated in socket,

2045


What is the permissible maximum flux density in transformer core?

1242


What the formula for calculating no.of earthings & size of earth strip for 100mX90m shop.

2367


How to calculate the Efficiency of Chiller

3353


What is process of anneling transformer core

1968


what is acceptable leakage current for 33kv cable while doing high voltage test for cable? how to calaulate the leakage current for 33kv or any rated cable?

4040


We have a distribution transformer of 750KVA/11kv/440v and an AVR (Servo Stabilizer) of 750KVA on the LT side of distribution transformer. Also we have an ACB of 1200A on the output of distribution transformer (that is on the input of AVR). We want to have an MCCB on the output of AVR. What should be the rating?

2106


How to calculate the time setting for star connection in star delta starter? For example 10KW 3PH Induction motor.

2630


What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works?

2044


block diagram of 2 ups system connected in hot stand by mode?

8067


Hello sir, pls send me hpcl technical test papers .i am. Appearing for the exam.

2722


Why do we use copper cable for HT Supply and why not Aluminium?

2013