Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is meant by directional power and reverse power relay ?

Answer Posted / mostafaghodrat

protection from motor becoming a generator.(reverse power)
Secondary zone of protection for internal faults.(directional)
good luck

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what are the industrail measures to over ferranti effect? how would the ferranti effect the power system if those remedial mearsure arent taken? how often does this effect occurs in real power system?

2155


What is force on parallel conductors ?

1083


In layman terms, what is the difference of Dielectric strength and dielectric constant when speaking of an insulating oil

2715


how to calculate the tarriff for an industry whose kva demand is 10 mva

1994


What is polar plot?

1187


what is earth-fault?when it occurs? to check where it occurs what type of test should we do?

1998


Can XLPE/SWB/PVC (P3) 7C X 2.5mm2 be replaced by Can XLPE/SWB/PVC (P2) 7C X 2.5mm2??? P3 vs P2

1864


why power not passes in plastic and rubber material

1977


list the advantages of RCCB over other circuit breakers?

1711


what exactly commisioning work does in electrical site work... LT side?..

1942


How could a garment factory benefit from renewable energy

2769


what is advertised hop count

1776


What will be result if we connect LT votage to the terminal of HT motor?

2149


Practical condition in 400KV Sub station:- Breaker(open) , isolator(open), Earthing (close) at both end e.g A & B. Now Open A Stn Earthing than Open B stn Earthing (Which have a 50MVA reactor) , AND suddenly show R,Y,B phase 704KV,573KV,118KV respectively. Que is without closing of breaker how it is possible.???? My Whats app No:07621840498 for Further Discussion. Pls experts suggest.

2095


I Need standard operation procedure(SOP)for 500kva Oil type transformer oil filtration & Procedure for IR value checking.

2899