Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

You have casted a column above your footing, and you found out
it is off its location by 5cm. What would you Do?

Answer Posted / rajesh.d.v.s.p.

i don't no in site but according to my knowledge if the column is with in the core there is no problem other wise any eccentricity u have change the design considered moment with respected to axial load

that was design the column with moment+axial load

P = P+ P.e

Is This Answer Correct ?    2 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the clear cover for shearwall?

1675


List out the types of roofs?

1194


What was asked in isro civil interview

1177


what should be RCC material i.e iron rod(mm)x cement x stone x sand for laying of slab L 42'x B 22'x tk 0.375ft = 1nos & column of H 17'x15"x8" 2nos.

2395


What are the benefits of rcc pipes over steel designed pipes?

1515


a solid steel rod length 2m dia and 20mm vertically hangs from celling and has a collar firmly atteched to it. above the collar an annular rubber washer of 40mm th. having stifness k = 5n/mm is placed. determine maximum stress in the rod caused by mass of 5 kg falling through a height of 1.2m.

2410


how to calculate quantity of cement,sand & aggregate for u.c.r / r.r masonry in cm 1:6

6286


why should we use 20mm graded metal only in vrcc?why we shouldnot use 40mm metal?

11304


what is the max. and mim. height of vertical post in informatry sign board which is used in highway projects.

2801


Design a reinforced concrete combined footing (rectangular) for two columns located 3.60 metres apart. The overall sizes of the columns are 40cm x 40cm and 69cm x 60cm and the loads on them are 1000 kn and 1500 kn respectively. The space available for the width of the footing is restricted to 180cm. The S.B.C. of the soil is 280 kn/mm2 use M15 concrete.

2669


What is the Roll of Water Bonding under VDF road?

2717


What are the RISKS during the project construction?

2340


why we use 19x9x9and 20x10x10 but not other

2204


Bitumen grades are 30-40,60-70, 80-100. what is mean by 30- 40

94977


Please let me know what is the simplest way of Calculating Mix Designs

2069