difference between circuit breaker and switchgear?
Answer Posted / m.radhakrishnan
Circuit Breaker is switchgear equipment. when short ciruit
condition abnormal current flow in the circuit. To protect
all the equipment in the power system network against
excessive over voltage or excessive current.
Is This Answer Correct ? | 0 Yes | 1 No |
Post New Answer View All Answers
What should be the percentage increase in length of the dead end clamp for bus bar conductor (Hawthorn) after hydraulic pressing and what should be the applied pressure?
Why do we pefer VCB over OCB?What are the advantages of VCB over OCB?
What is the formuala to calculate the rating of motor protection circuit breaker
for 750 kw LT load what will be the ht kva
how to calculate the change over time for star delta starter for different KW motor?
In electrical locomotive engines, the DC series motors is being used as traction motor. But in new engines like in WAP7 & WAG9 the 3-phase squiral cage induction motors has replaced them. So can someone tell me the advantages of induction motor over dc seris motor in engines points of view....???
what is the difference between switchgear and circuit breakers and is there any difference between outdoor and indoor switchgear and circuit breakers , and how would you differentiate between switch yard and substation and grid station . thanks
sir i completed apprentice in TNEB.apprentice is eligible for 'c' licence
who many types of fire explane with exmple
what is the criteria for selecting fuse rating in 1phase, 2phase & 3phase welding sets?
solar inverters was not connected to the nuteral link .this nutwral possible to any other systems
I have a current transformer with 1 main reading meter with transformer outside the building and a control panel having 5 CT reading meters with black round coils inside the building. I want to know, A) when current pass through the Transformers, will the current be reduced or be the same and after that B) when current pass through the CT meters with black round coils, will the current be reduced or be the same. C) in the above process will the reading of the main meter be same or different, from the total reading of all the 5 CT meters.
is there any current and voltage drop on liquid resistance starter water/soda tank ?
Please clarify, 1. Is it required to lay two runs of GI wire along with Armoured LT cable if it is laid between one big mains (63Amps TPN SDF) to small main (32A TPN SDF) with proper glanding termination? 2. If the armoured cable with proper glanding is laid from DB to CNC machine, is it required to run two runs of body earthing to the Machine from DB? 3.If the armoured cable with proper glanding is laid from Substation to Hangar, distance is approx. 100 mtrs, is it required to do earthing at shop area though the primary termination at substation is earthed through gland.
How wire size can define in electrical wiring? What is the ratio?