Boiler capacity is 5ton, what will be the feed water tank
capacity?
Answer Posted / devinder singh
MINIMUM 200% EXTRA
Is This Answer Correct ? | 1 Yes | 1 No |
Post New Answer View All Answers
why do you consider yourself a suitable candidate for this position
DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.
What is LB-SR.
How to calculate power press toneage
What is surging in a centrifugal compressor ? How it occur's ? How is antisurging done ?
How We Calibrate the vaccum transmitter?
why airtel use + 24 volts and other operators use -48 volt
By any way can we increase the B check hours from 300 to 500
im try to calculating seawater flow required for SW-FGD system. I need a guide, equation or method to do it, can some one help me! Thanks very much
LAPT working in alternator / generator
what's the moog valve
can dp type level transmitter work in under vaccum condition
what is restricted earth fault explain in details
Looking for Bently Nevada surplus 3300/52-01-00-00 Reverse Rotation Monitor , 4 pieces.
procedure of how to generate power in solar plant.