Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is scanner air fan & how dose it work & is there any
interlock in power plant

Answer Posted / brajesh_genus

nothing but to remove flame scanner lance dust & taking
suction from atmosfier air and purging to lance & no interlock.

Is This Answer Correct ?    6 Yes 11 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is LB-SR.

3070


Which will have more strain energy 1.Spring 2.Circular disc 3.Solid square plate.

2471


what is restricted earth fault explain in details

2105


what does mean by kva rating

1572


Why superheated are started before I'd and rd fan?

2227


what is the difference between compensated & normal drum level in boiler drum?

1860


why do you consider yourself a suitable candidate for this position

7505


why is the in steam turbine axial displacement of active side thrust pad is positive and non active side thrust pad is negative.

3312


im try to calculating seawater flow required for SW-FGD system. I need a guide, equation or method to do it, can some one help me! Thanks very much

2068


why airtel use + 24 volts and other operators use -48 volt

2692


Looking for Bently Nevada surplus 3300/52-01-00-00 Reverse Rotation Monitor , 4 pieces.

3467


DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.

1046


our 125 kva DG does not start in AUTO mode works normally in MANUAL mode please give me a solution.....

1763


By any way can we increase the B check hours from 300 to 500

2255


What is surging in a centrifugal compressor ? How it occur's ? How is antisurging done ?

2482