Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why is the earth pin in a 3-pin plug the longest and the
thickest?

Answer Posted / a.baral

earth pin is longest becoz it will touch the ground first
it is for safety purpose
but the thickness case is R=pL/a
a=area
as thickness is more i.e area is more
Resistance inversly propertional to area
area more means resistance is less
current always flow from high resistance path to low
resistance path
fault current pass through that thick point

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details.

2473


11 kv input, 66 kv input advantages

1385


what is DRP panels?

2132


What difference between ref protection and differential protection ?

1838


1.Z transform always lies around ? a) origin b) pole c) zero d) z=1. Multiples Mcqs which is bother me can’t find answers on internet. Some help required with little explanation . Note: this is not homework or related to any test. Thanks

2464


What is the exact formula for one weber of magnetic flux?

2135


What is voltage ratio of a transformer?

1178


For small size, high frequency coils, the most common core material is- a. )Air b. )Ferrite c.) Powdered ion d.) Steel

2984


DERIVE AN EXPREION FOR MAXIMUM POER TRANSMISSION, WHAT ARE ITS APPLICATIONS.

2246


if the load is 80 amp for main fuse and 100 amp for breaker so how can we calculate the cable size (cooper ) .

2069


wat is d diffr btw shunt coil and trip coil in VCB?

2826


why current flow to the opposite direction of flow of electrons???????????

2155


why wire sizes are 3/29 or 7/29 and why not wire sizes are 2/29 or 6/29?

5142


What is the formula to find out two phase active & reactive power

2182


What is mathematical model of a control system?

1140