Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what happen if i change the polarity of ac when it is
connected with motor

Answer Posted / sameh el-azab

-if the motor is single phase nothing happens because the ac wave inversed automatically
- if the motor is three phase there will be two case:-
1- if u change two line the motor direction is inversed
2- if you change the three line nothing happens

Is This Answer Correct ?    15 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how can get electrical c licence.now i am working in spining mill , transformer capacity 2750KVA. SANCTION DEMAND 2250KVA. PLEASE ADVISE ME . MY CONTACT NO 09944226823

1844


How many VSC based HVDC are there in India and the world

2286


If SFU is Switch Fuse Unit, What is the expansion for FSHF in Electrical Engineering?

2650


What is the difference between shortcircuit current, rated current of cable & MCB with example? What will be the size of cable required for 5.5 KW motor (Full load current 10 Amps approx.), Starting current with DOL is 120 Amps. Aprrox. Short circuit current with LLLG fault is 2000 Amps Approx.

2103


who can measure the size of power cable?

2211


A 7 storey building has a floor area of 35,000sq.ft on each storey. On the ground floor 11KV electrical sub-station is to be erected. A load of 3kw for every 400sq.ft (p.f is 0.8) is proposed for each floor. fire pump 7.5hp, water pump 5hp, lift 2 nos, each 10hp and 20shop load of each shop is 5kw. calculate a. load each floor b. total load of building c. L.T feeders for aech floor and from transformer to main. d. distribution diagram e. capacity of sub-station/capacitor bank f. line diagram

2889


What is earth system using on the floater TN-S or TT. Iam not sure and what ICCP

1792


What is the reason for using a GE G101 MCB in place of an EP102 MCB if both are capable of AC circuit protection?

2717


derive DC RMS value for half wave rectifier?

3244


why 15 kw motor winding resistance is low then 5 kw motor winding resistance?

2896


how to modify DOL control panel into Delta Y connection?

2014


what reactive how to maintain

1891


State any two nuclear power stations in India, with their generating capacity.

1955


EXPLAIN WHY THE SURGE CURRENT RATING OF AN MCCB OR CIRCUIT BREAKER DECREASES WITH INCREASE IN THE RATING OF MCCB OR CIRCUIT BREAKER.

2070


how to calculate short circuit current for the busbar

1575