how long will take to burst/damage for a CT when secondary
in open condition?
Experienced: During switchgear testing(Primary current
injection test) some of the CT are in open condition, but
nothing happen's why?
Answer Posted / sheikh
Every one C.T has it,s saturated voltage status which called
knee point voltage if any one ct has been crossed over the
limitation of knee point then will be chance to burnt out
the ct .
| Is This Answer Correct ? | 2 Yes | 1 No |
Post New Answer View All Answers
Why IR value of the (HT cable Plus synchronous motor) is less while individually having IR values in GΩ?
What are different types of control systems?
why the starting voltage drop in a cable needs to be limited?what is percentage of the voltage drop allowed during starting?
can i use ups power as a raw power for another ups
What is the function of a neutral reactor.
how can we save enegry by using VFD for Resiprocating Air compressor which is having more unloading running hours
kindly send me 11KV MV motor differential protection procedure by primary injection method.
What is the maximum breakdown voltage of 11KVA and 66 KVA power line and how it is calculated?
hi I have done 3 yrs diploma in electrical engg after 10+2. I have 16 years of work experience into design proposals sales and engg application development in LV/MV swithcgear and sub station automation field. I want to apply for immigration to new zealand but I am not sure whether I qualify or not since I dont have a degree. Can anyone advice? Thanks Riz
How can get elongation of 2 k.G aluminium, if elongated aluminium dia is 2.5 mm?
I'm generating a pulse of 3V with frequency 80Hz (12.5ms time period) and pulse duration 0.125ms and feeding it to a transformer since i want the pulse to get amplified around 60V. At the output amplification s happening but the pulse is changed to a spike, can you tell me what could be the reason? (an ordinary transformer 220V-12V stepdown transformer is reverse connected ie. now it is 12V-220V stepup and voltage amplification happens)
I Have 3 Phase 10 KW AC Alternator i found one phase weak, so what will be the reason & what action shouls i take to rectify the same.
we have require a Motor (1500kW, 6.6kV, 50Hz) which shall operate at 1500rpm during 30min and after it shall run on 500rpm during 15min. The same cycle shall be repetitive during the whole working days. Which method is best and economic to achieve such type of task. VFD, VVFD, Pole changing motor etc.
for what purpose the star point is done in ct
how can motor both beasrings insulation resistance can be check?