what will happen if one of the phases from a 3-phase motor
is disconnected?? stop/run at 2/3rd speed or run at same
speed????
Answer Posted / rangan
IT'S RUN AT HIGH SPEED .
| Is This Answer Correct ? | 0 Yes | 1 No |
Post New Answer View All Answers
when we have to purchase the transformer by own i.e how much load will preferred HT connection?
in a solar power plant,we are going to step up the voltage 350V to 33kv, and to 132kv GSS. i want to ask that if it is possible that 315v/33kv is not possible because we also use 315v/11kv. or it should be 415v/33kv? is it effects generation or losses? the second question is-generation is depends on LV winding? or LV winding design for generation voltage?
A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.
How 3 phase invertor works?
How many types of colling system it trformers?
What is primary and backup protection?
In Plumbing services What are accessories we consider for a bathroom?
what is residuel magnetism. and how order lead acid batteries for 24 volt. emergency lighting system.
What we mean by vintage of an engine+Generator?
please send me latest & previous years question papers for IOCL Technical level questions
What does the letter CTNM in negative phase sequence relay means?
What are the classifications of oscillators?
I have 4 DG set with 1500KVA rating. system breakers are 11KV & alternator are 415 Volts. Between alternator & breaker one stepup transformer used. i want to Know what is max. resistance for body earthing & 415 & 11KV V Neuteal earthing. my fault current is 14 times for 2 sec.
What the difference between three phase contactor (coil 110vac) & three phase SSR (control voltage 110Vac)? May I use contactor in place of SSR?
can any one suggest me the tilt angle of my solar pannel ?? or tell me how can i know the fix tilt angle of my solar pannel?? my cordinates are 31.503629,72.993164.