Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what r the parts calibrated in gc

Answer Posted / shanthi

Injector precission
Liearity of the detector
Oven temperature calibration
Carrier gas flow rate calibration

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why we used in n-butyl acetate water content terminology while in ethyl acetate we used moisture content terminology?

1796


If we do accuracy at same concentration at which linearity planned,what is the need to do linearity separately?

2240


What is the formula for relative diffrence for standard solution in solution stability in validation?

738


How do we fix the sample concentaryion in hplc method development. What is the basis?

1141


how many types of balance calibration test?

2249


What is shaking level in GC?

739


in which situation require to use paddle and basket?

671


CAN WE DETERMINE THE PEAK PURITY IN GAS CHROMATOGRAPHY ANALYSIS?

1149


why glutent are detected in the rice cereal baby food product even manufacturer claimed that they are using rice and milk only?we have using ELISA to do the test,and rice supposed not containing any glutent,rite?We already repeat the test so many times and it still detected.just wondering where the glutent came from?

2706


how decide the clining method and cleaning method validation require for this perticular products?

705


If change in specification which parameter require to do for validation? if change in chromtographic condition then which parameter? if api change then which parameter? if change composition then which parameter? if old method not work out then whicj parameter? if additional one impurity added then which parameter of validation require to do on above each conditions? elaborate separately

796


if identification threshold crosses the limits then what next step?

798


What is split ratio in Gc? Splitless? how requirr to select?

818


For titration in anhydrous media with perchloric acide, if lack of titrator, Which indicator is been used for replacement. How calculate pH of test solution to choose suitable indicator?

2263


Identify problem faced when mass spectroscopy is used with HPLC system ?

1802