You are given 220 V supply source, four wires, an ammeter
and voltmeter. There is no any indication or description on
meters. How will you identify which is ammeter or voltmeter?

Answer Posted / ashok mishra sddiet

connect both in series with the source as amitter having low resistance will show high reading and voltmetre having high resistance will show low or almost zero

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

with out colour codeing on conductor how can be find what is r,what is b,what is y phases.....

1507


different aspects of voltage stability

1538


How to calculate KVA/VA rating of PT or CT from primary & secondary voltage or primary & secondary current?

1991


Is it true that in the 3 phase transformer, the limbs of the core are at 45 dgrees to each other. if true, why?

1588


i have some screw comprressor with 630kw power,i have established them with simple star to delta circuit,by the way there is so much inertia when the screw comprressors start, can you offer me contactors power with 400vac or any cataluge to choose the contactors

1413






What is the function of attenuator in cro?

741


What is the meaning of floating point earthing in battery backed systems ?

1488


what are problems caused by the pdu in rack server

1460


armature winding of dc machine produce alternating emf then it convert in to dc by using commutator.But only we consider armature resistance why don't we consider inductive reactane effect?

1640


I am having a 42KW 3 phase electrical heating furnace, heating element is 80/20 nichrome material, my connections is made in such a way that 2 star connection compromising 2 coils per phase so totally 12 coils, shall if i use it unbalanced star condition (instead of 2 group of 3 phase or 1 group of 3 phase, connecting 4 phases of 5 phases) what will be the consequences and is it acceptable?

1262


TYPE'S OF BREKAR ,WHAT IS TRANSFORMAR & SAFTY. STARTER DOL & STAR DELTA STARTER.

2110


In cable sizing calculation (determining the max route length of cable) why we choose the shortest length between cable length of full load current Iflc & starting current Istart?

2783


Good day everyone,currently in our premise we using 30kw slip ring motor with resistance bank which we use as forward and reverse at conveyor bar handling. So,my question is how do we calculate the resistance bank which is suit the motor. Kindly,assist me... thank you

1277


In all analog voltmeters or ammeter showing some small size symbols. as well as a star and in star 2no. digit, resister symbol,and other. what is that's meaning ?

1588


why we use the 100% and 95% stator earth fault protection for the synchronus generator ?

1839