Hydro P.P. run @ 600 rpm,8pole, Nucler P.P @ 1500rpm 4 pole ,
ThermlP.P @ 3000 rpm 2 pole.Why this diffrence??? when we can
generate electricity @ 600 rpm then Why we had incresed speed
in NPP & TPP???
Answer Posted / 7anoter4
The synchronous a.c. generator rpm[rotations per minute]
depends on the mechanical drive rated rpm –Diesel Motor
could be high speed –for 60 Hz systems up to 1800 [I did
not see 3600] and the lower limit may be 100-150 rpm.Low
speed D.G. consume per kwh is lower so for 40 years will be
a huge advantage.
The dimensions [and weight] of the motor-and of the
generator too-decrease as the speed increase [and the price
also].The turbo-generator is 2 poles generator usually as
this is the minimum equipment and installation cost.
| Is This Answer Correct ? | 0 Yes | 3 No |
Post New Answer View All Answers
H.t motor 6600 volt to same motor lt supply 440volt supply applyed to h.t motor to effect....
How can you calculate the size of the down conductor cable for the lightning protection system. Is 70mm2 cable can replace 95mm 2 bare copper cable when the copper tape size is 25Wx3 thk mm.
sir i have a car stereo system and there is jack on him so can u tell me a way to find out their power terminals on the jack or on the circuit board"
Why is it prefer to initiate circuit breaker failure by "86" lockout relay not by "94" tripping relay ?!
I have a 380 KVA DG set. How can i find out 1. My Fuel Consumption per hr ? 2. Electricity produced in 1 Hr. ? 3. If load varies then how does it affect fuel consumption & electricity produced ? Please HELP !!! Really need an answer.
What aturn on methods of scr?
we have consol make 3 phase servo stabilizer for cnc m/c. while installing the earth neutral voltage is 1.7 volts at stbilizer off condition and when stabilizer get on en voltage reaches 4.8 volts (new earthing is done and neutral is helthy condition all phase to neutral volts 440,442,441 v)why this happen.solution for cause.
what kind of quetions will ask in BHEL in interview? Plz help me?
3Cx240 & 3Cx300 sqmm Al. cable from lv side. What is the calculation for this cable??
1)how to reduce the value of tan delta of trasformer and CB,bushing,CT&PT,CVT ? 2)how to reduce the resistance of CB contact and its operating time? 3)plz.....send me the project report on conditioning and monitoring of substation equipment on my email id (gusaiyogendra03@gmail.com)
sir i applied for hpcl(electrical).i want to know from which subjects most of the technical que will b asked.and pattern of the written test.pls help me
ASTM D 3455 - Standard Test Methods for Compatibility of Construction Material with Electrical Insulating Oil of Petroleum Origin has been used for Testing Transformer Oils with a product placed in it. Aged Control Oil has a Power Factor of 0.032% at 100°C. Aged Oil with a Test component has a Power Factor of 0.093% at 100°. Is this increase acceptable? If not why? How much increase is acceptable?
11000volt DG set carnt kaise banvay
What is meant by Im=30mA@Vk/2. How to know the kee point voltage for CT design
at what basis/standard we have to arrive the current density of aluminium/ copper in busbar?