Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is formula mv convert to temperture

Answer Posted / dilip jha

T=mv*25

Is This Answer Correct ?    5 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

sir,would you please send me the Hindustan petroleum corporation limited papers(HPCL).my e-mail ID is ujjwal_sharma1983@yahoo.com

2320


Which is the best field foundation bus. ( FF ) Yokogawa, Honeywell or others ?

1787


What is critcal speed. what is resonant frequency. why we want to cross crtcal speed on higher RPM (early).

2141


why we use cascade control and feed forward control in 3 element drum level control measurement of steam drum .what is cascade and feed forward control system ?give example .

2870


while i check zero check for dp flow transmitter some fluctuating came (0 to 458 kg/h) what is the reason?

1893


what is the importance of CV in the control valves? how it is calculated?

2434


WHY THE DEGREE OF VALVE PLUG AND VALVE SEAT IS SLIGTLY DIFFERENT I CONTROL VALVE TRIM DESIGN

1982


Can Any body tell me how to check Modbus Settings in ER300N L&T trivector meter?

2592


i have used level transmitter in starch cooking preparation tank. tank total height 2mtr.sometime LT display shows some error value when tank is fully empty and diaphragm side i already checked okay no problem in diaphragm area. field cable checked 24volt and mA shows correct value while tank empty mA is 4mA. 4mA i needed that 0% but display showing 10% or 15% percentage values are varying continously please give any good solution for me.....

1461


what is the reset offset and control system in instrumentation

3605


the output of the common trasmitter protocol in qatar gas are the following

2011


Can anybody tell me which type of question are asked in the interview for the FORMULATION(Pharma) as a instrumentation engineer, & question in building managment system.

2012


why we r opening HOT BYPASS valve during startup of a compressor?

2093


how can i check vortex shedder bar it is ok? if there is ohms condition are shown correct?

2215


what is easiest way to read STL language in PLC?

3127