What is the use of conservater, bucchos relay, breather in
a transformer?
Answer Posted / rajput deepak
# 6 Bucholz relay is the protective deivce which protect
the
transfomer from overload,overheat,short ckt protection.
when ever any over load or short ckt happen ,the first
thing increase which is temp of transfomr and this relay is
connected with temp sensor controller and these realy has 2
NO contact first alarm contact and another is tripping
contact.
breather as name indicate ,when the temp of oil get
increasing it expand and Dry air of conservator tank goes
out,after cooling the oil ,again conservator tank need Dry
air ,which is supplied by breather and silica gel takes out
the moisture from this air.
conservator tank is stored the cools oil.
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
in cvt,there are two windings,1a,1n and 2a,2n.in my one project i use only one winding i.e.1a,1n. the other winding is not in use, so i connect it in open delta and want to close it by ibsertibg thermal resistor. the output of cvt is 132kv/115/sqrt3. plesae tell me exact value of resistor, so i may close it to avoid the resonance phenomenin. send me answer on this email adress please. aetcon-po@aetcon.com
What is Antipumping Function & If we have C.T how we find the Ratio ?
what is parellel power factor correction?
How would you calculate power loss in a resistor?
i am in need of AC SYNCHRONUS MOTOR 30KW. ANY ONE KNOWS THE MANUFACTURER OF SAME. ALSO MOSFET AC CONVERTER 20KVA CONT.OUTPUT.
how to find the capacitance value of the motor while running??
WHAT IS THE MEANING OF BALANCED / UNBALANCED IN STABILIZER TYPES.
what irequirment need to be followed when working on live equipment
what about the power of wattmeter at starting and loding?
My load is 1635 KW. & current pf is 0.884, I have to improve it for 0.99.Please suggest what KVAR value is needed?
1600 KVA ka transformer hi aghar lt side par 800A aur voltage 420 ho to HT side ki cable ki rating keya ho gi?
HOW WE CALCULATE CURRENT IF THERE ARE NOT PRESENT ANY AMMETER OR MULTIMMETER??????
what is the usage of microcontroller in the panel board?
I am inpecting a 10kVA UPS what tests should i do and should i observe?
Sir, My doubt on cable sizing calculation, Load:74 KW calculated cable 1 run 50mm2. Now client asking us to reduce cable size by increasing runs. Sir, My question now when my mind strikes with 2 options 1) Divide load 74/2 = 36 and calculate cable for 36+36 making it 2 runs or 2) Simply i can divide 50mm2 /2 ie. 2 runs of 25mm2 Please suggest me sir