Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

IN 3 PHASE INDUCTION MOTORS SOMETIMES COPPER BARS ARE PLACED
DEEP IN ROTOR WHY..?

Answer Posted / raul

This design is known as Deep bar rotor, which is basically
a modified rotor design in Squirrel cage induction motor.
During starting, the rotor frequency (i.e. Fr = slip *
supply frequency) is very high and the rotor reactance
value is very high, due to which the rotor current is
restricted to the near slot rotor copper and the area of
cross section of the conducting rotor conductors reduces
and the net resistance is increased due to which the
starting torque and the slip at which the max. torque takes
place also increases. And as the rotor picks up speed, the
rotor frequency and hence rotor reactance starts decreasing
and the complete deep bars carries uniform current and
torque reached steady state torque.

Another design with the almost the same above principle is
the DOUBLE CAGE ROTOR

Is This Answer Correct ?    6 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

if there is nutral in phase why we use earthing wire and grounding? even at fault condition the fault current flows to neutral (it is a lower path)

1825


what is the string efficiency

5227


How will you define capacitance?

1149


specific difference of ICT&Auto Transformer

1882


How does an oscillator differ from an amplifier?

1146


What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side

1449


What is lc oscillator?

1180


hi friends if you have any 400KV Substation Erection and installations Drgs please send to me.My email id:kandi.suresh441@gmail.com

2912


How can we measure earthing resistance test (Earth meggar) of Transformer neutral pit while in live condition?.

2129


how we decide wire gauge for ac or dc coil and what is the basic diff. B/w these two coil?

2187


What is the important precuations need tocarried out while working with Electrolite in Battery PM?

1894


How to synchoronize the generator (with gcb,GT) to grid????? ????? from Grid iam getting power (rated 400kv/20kv) through GT and its goes to UAT.,,ST.,, now my generator(rated 20kv ) ready.,, now iam closing my GCB.,, in GT iam suddenly giving 20kv on that Gt.,, what will happend

2070


WHY IL=IPH IN STAR AND WHY IPH=IL/1.732 IN DELTA? WHAT IS REASON BEHIND IT?

6343


A ray hit a smooth regular surface at an angle of 20 from the normal. Calculate : 1. The angle btw the incident and reflection ray. 2. The angle of deviation.

1917


Why GRR starts from 60% of motor speed why not less than 60%?

1693