Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

IN 3 PHASE INDUCTION MOTORS SOMETIMES COPPER BARS ARE PLACED
DEEP IN ROTOR WHY..?

Answer Posted / raul

This design is known as Deep bar rotor, which is basically
a modified rotor design in Squirrel cage induction motor.
During starting, the rotor frequency (i.e. Fr = slip *
supply frequency) is very high and the rotor reactance
value is very high, due to which the rotor current is
restricted to the near slot rotor copper and the area of
cross section of the conducting rotor conductors reduces
and the net resistance is increased due to which the
starting torque and the slip at which the max. torque takes
place also increases. And as the rotor picks up speed, the
rotor frequency and hence rotor reactance starts decreasing
and the complete deep bars carries uniform current and
torque reached steady state torque.

Another design with the almost the same above principle is
the DOUBLE CAGE ROTOR

Is This Answer Correct ?    6 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

TELL ME WHAT IS INDUCTOR AND CAPACITOR WHAT IS IT BASIC OPERATION ANDFUNCTION?

1973


What is the different types of cable & current capacity of cable

1882


what is the difference between STAR and DELTA connection and application wise how it can be utilizedd

2155


State thevenintheorem?

1012


difference between the applicability of nortons and thevenin theorem

2035


what is difference between 2 pole structure and 4 pole structure in transformer yard

5963


how to store the thunder power?

4387


What is meant by Low Resistance Cable and High Resistance Cable.

1863


if the number of poles generated in stator and rotor side of an induction motor are different then what will happen and why?

1825


what is servo motor and how it works?

2232


Explain cos(theta) and Sin(theta)

2035


why zero sequence impedance measurement is not applicable for single phase GT

2133


This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details.

2421


Is there any Electrical supervisor license which gives permit to work whole India rather than individual state??

1816


Is a contactor (or master relay) required between incoming lines and a VFD? The question goes to safety. If a contactor were used before the VFD and an e-stop engaged then the motor will coast to a stop (i.e. VFD loses power) instead of stopping much faster if the VFD braking fucntion were used. It would make more sense to keep power on the VFD.

2103