Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is LAS in foundation fieldbus protocol?

Answer Posted / carl_ellis

What is Foundation Fieldbus LAS?

Link Active Scheduler (LAS)
A Link Active Scheduler (LAS) is a deterministic,
centralized bus scheduler that maintains a list of
transmission times for all data buffers in all devices that
need to be cyclically transmitted. Only one Link Master
(LM) device on an H1 fieldbus Link can be functioning as
that link's LAS.

The Master and Primary Backup Link Active Scheduler (LAS)
shall reside in the host control system in redundant H1
network interface cards.

An additional backup LM Link Master (B/U LAS Link Active
Scheduler) shall be configured for all networks and shall
reside in the network device with the lowest field node
address. The Backup LAS should be placed in a separate
device that does not have controlling functions.

Primary and secondary interfaces should sit in separate
backplanes with separate CPUs, preferably in separate
control panels. Similarly, the primary and secondary power
supplies should not share the same backplane. Having
redundant interface cards, CPUs, and power supplies in the
same backplane is self-defeating since the backplane is a
single point of failure.

Each network shall be configured for automatic fail-over to
the Back-up LAS in the event of Master LAS failure.

Carl Ellis
Measure First

Is This Answer Correct ?    4 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I have completed B.E. Instrumentation & control in 2009. i have 3 year industrial job experience in chemical plant.now, I want to join M.E. in external. so, Plese say easiet way and good institute name.

1939


What are the interlocks we have to check during the start up of LP/HP compressor?

2037


Im having problems with interfase betwen SPI v7.0 and SPPID v5.05. Previous versions of Intools shoul be fixed with SPPIDproj.ocx file. It was necessary to replace this file with one that allows the connection between different versions of SPPID. It is necessary in the current version to do the same?Thanks

2363


A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.

2214


TEMPERATURE VARIATION FOR FREQUENTLY.

2096


I am teja. I am studying Msc(tech) Electronics and Instrumentation (3years course) in Andhra university. But my course is not recognised by UGC and AICTE. Please tell me the job opportunities after this course. And i fineshed PLC course in IGIAT ,Vizag.Also complted my short term coure in SCADA, Seimans WinCC in ATI,Hyd.After Msc can i join Mtech for good job? or phd. How i can get good job in INdustrial Automation Side. Please give replay.Because this is my life matter.

2133


How to calibrate an pressure gauge with yantrika test bench?

2945


What is intrinsically safe system?

1193


Sir , i have completed my M.Sc In Instrumentation and presently working in Maintenance department 3 yrs Exp , is there is any possible for work in offshore ..

1869


what is the PC interface and software for connection to ABB logic module “ LM011-CE18RAC “ ( for Programming ) ??

4073


types of cable..? Use of every types of cable..?

2183


What is Droop? What is Step/Gradient Limiter in Turbine Governor control?

3452


What is difference between Ionization heat and bimetallic heat

1724


I want to know the questions asked in ONGC interview(after being selected in the written exam) for Instrumentation branch.Kindly help.

2335


how to calculate orifice sizing? and tell me if pipe size bet 50mm t0 200mm then we can use pipe flange??? and above 250mm pipe size should i use D & D/2 Flange? is it right or wrong?

1926