8mm steel not
available at site
used bar 8mm and
150cc please tell
me specing i used
10dia bar write
formula please
Answer Posted / ujjawal u daharwal (sgsits, in
very simple
Note: d1^2/s1 = d2^2/s2
where, d1= dia of available Bar
s1= spacing b/w available
d2= dia of new bar
s2= spacing of new bar
in this case; d1= 8mm, s1=150mm, d2= 10mm &s2= ?
8^2/150 = 10^2/s1
s1=234.375 mm c/c = 230 mm c/c ANS
| Is This Answer Correct ? | 8 Yes | 0 No |