Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is dedicated earthing

Answer Posted / sachin shindolkar

Dedicated earthing is normally word used for the earthing done for the electronic equipment ( IT Server or projector in multiplex ) having high valve and can damged due to not having proper earthing or surge it should have neutral and earth 2volts and the single core copper leads is directly taken from earthing pit to the equipment without any joint so that the earthing should be get the minimum resistivity.

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Practical condition in 400KV Sub station:- Breaker(open) , isolator(open), Earthing (close) at both end e.g A & B. Now Open A Stn Earthing than Open B stn Earthing (Which have a 50MVA reactor) , AND suddenly show R,Y,B phase 704KV,573KV,118KV respectively. Que is without closing of breaker how it is possible.???? My Whats app No:07621840498 for Further Discussion. Pls experts suggest.

2035


Comparision of Air break circuit breaker, SF6 Circuit breaker and vacuum circuit breaker.

2309


can the measured percentage error during calibration of single phase energy meter be negative?

2352


State Maximum Power Transfer theorem.

1202


Which material is used for the core of a transformer and why?

1048


what is the ms flat constant for calculating earth mat design calculation?

2468


Why efficiency of generator is higher than motor at a particular load?

2003


why fractional pitch winding generally used in alternators?

2899


Percentage losses in power generation?

2939


What are steps to be taken while designing of DYN11 distribution transformer to achieve magnetising balance?

3485


how oti and wti connections are different from each other?

2010


HOW TO CALCULATE THE HEAT AND LOAD OF LT-SUBSTATION WHICH CONTAINS 2*1MVA TRANSFORMERS,LT-SWITCH BOARD,MLDB,ACB,BUSBAR,ETC,......?

2056


how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating)?

1925


What is Negative Potential Bias

2234


Discuss the effect of sudden loading of an induction motor

1819