what is transformer tap change HT side and LT side

Answer Posted / somu0507

Transformer tap changer is placed at HT side. Following are major advantages:
1- Finer (smoother) voltage variation for per turn tap changing.
2- Lower current to handle than LT side.

Is This Answer Correct ?    13 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the types of HT motor testing

3026


Could the power factor on electrical system can affect the registration of the kwhr meter or the CT/PT? 

1462


ITI r/tv trade APPLY (J.T.O VACANCEY) ALSO INCLUD AITT ELECTRONIC,WRITEEN XAM DONE 23.03.10 BUT NO RESPONCE WHY ANATHER ID gopal_gh007@rediffmail.com

2959


I want to make street light with solar system ... What may I do for procedure and how much of estimation for each material ... If any one knows guide me and inform this id : aravindd7@gmail.com

1352


how can we say that stator magnetic field rotates with synchronous speed?can we derive?

1310






what is the difference between earthing and unearth

2377


What is touch potential and step potential?

1631


Determine the BTU size of an aircon for 20 sq metre room

1457


I completed iti in2004 I was worked in A grade contractor can I get c licence

1265


in cvt,there are two windings,1a,1n and 2a,2n.in my one project i use only one winding i.e.1a,1n. the other winding is not in use, so i connect it in open delta and want to close it by ibsertibg thermal resistor. the output of cvt is 132kv/115/sqrt3. plesae tell me exact value of resistor, so i may close it to avoid the resonance phenomenin. send me answer on this email adress please. aetcon-po@aetcon.com

2165


what happens to the water pump if ground water level is slowly decreasing?our water pump is varying from no-load full-load due to this problem

1220


In our plant we have installed new MCC with ELR and CBCT which is detecting some leakage current in the system but it leading to some confusion when to check that in which feeder which is drawing current we put off the whole panel itself but still CBCT detecting some leakage current so can anybody ans me , where i am going wrong or how to detect whether its actual leakage or CBCT malfunctioning.

1716


how does high earth to neutral voltage affects electronic circuit?

1296


in 6.6 kv vaccum circuit breaker vaccum bottole vaccum capacity ????

1574


An 8 pole, 50 Hz, 3-phase IM is loaded to a poing where pull out torque will occur. The rotor resistance per phase is 0.3 ohm and motor stalls at 650 rpm. The slip when motor stalls is A 1 B 0 C 13.33% D 10.33%

1414