why transformer fuse wire is very thin as compared to home
fuse wire while voltage lavel is low
Answer Posted / danny
fuse is 2 breaking excess current hence transformer has less
current but high voltage,in home the voltage is already
transformed into current hence bigger resistance wire is needed
power is transported in form of voltage 2 avoid loss as
power loss is current/votage
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
how power trnafor from 1 point to another point in bus bar ya transmission line( voltage trnasfer from 1 point to another poin)
What are the advantages of nichols chart?
What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works?
what the function breaker failure scheme, how is it operated
how to calculate differential current when we testing differential relay..suppose we have 1000kw generator,630amp VCB,what value we should put /inject so that relay trip the VCB? PLLZ justify ur comment
what are types of encoder
what is the difference between vector scale and vector diagram?
what happen if the supply is given to the stator of the 3phase induction motor with out assembling the rotor ?
how to decide the panel size like MDB ,SMDB PANEL SIZES
how many types are their in switchyard or substation(like D,I TYPE), what is differant between them
High speed earth switch operation with diagram
why are distributed windings generally used in alternators?
3 phase Motor will be given 2 phase after 2 to 5 second we given 3rd phase so Motor Run sum-time in forward or sum time run reverse direction. All time phase sequence is not change. Why motor run in reverse direction? Please Explain........
How can claculate to attain the desired PF in the line ( HOW Much KVAR is required ) Pls Give the formula? Equate Petrochemical 0 1 how to calculate sizing of NGTR (Transformer rating,Loading resistor value and Current rating of resistor) and what is the X/R ratio. Details : 11kV,Capacitance 1.73532 micro farads,40kA for 1sec. 0 1 What will happened. if we feed 3phase supplay to the stater with out insert the rotor. How much current will flow through the stater winnding? Equate Petrochemical 0 1 What is required of exietation to the alternater. 0 1 why star point of HT motor not earthed? Equate Petrochemical 0 1 Why we are getting low voltage in star connection? Equate Petrochemical 0 2 What's ND relay & it's functions? Equate Petrochemical 0 2 How instantanious short circuit current is calculated? its formula? Equate Petrochemical 0 2 What is servo Motor? What's the advantages of this motor over Induction motor? Equate Petrochemical 0 2 What is core CT & it's function? Equate Petrochemical 0 3 what is meant by star/delta voltages as 440/220 in a 3 phase induction motor, and why it should be connected on STAR IN 3 PHASE SUPPLY L & T 0 4 What is required of exietation to the alternater. KNB 1 23 what is the design voltage for 6.6KV 2000 KVAR HT capacitor? Consultancy 0 3 Pls explain about vfd control?Where it is used, Give some example? siemens 1 22 Please explain me abt PQ diagaram in the power sector. 0 9
what should be the acceptrd value of winding resistance for 2.5MVA transformer