Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why single phase induction motors are not self staring ?
how can we start the 1-phase Induction motor ?

Answer Posted / abhimanyu kumar gupta

Single phase IM given single phase supply given to stator
winding an alternating magnetic field develop in stator and
produce alternating flux and collides with rotor winding and
produce induced EMF at rotor since the rotor winding are
closed this produce induced current in rotor.
Due to this induced current in magnetic field of alternating
nature and this nature is not rotating. Both magnetic field
in stator and rotor are Colline's so resultant torque rotor
will 0. Hence single phase IM does not self start.
In order to make motor self start an external force to the
rotor should be given because of locking of field will
disappear.

Is This Answer Correct ?    3 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is quality factor in series resonance circuit and calculate the factor of voltage magnification? how it happens?

2018


Single line diagram for dbb (double bus bar)system.

2003


BSNL TTA EXAM QUESTION

2219


HOW TO CALCULATE HV TEST VOLTAGE FOR ELECTRICAL EQPT.

2268


A 400KVA transformer has 400 Hz frequency. If the frequency is changed to 50 Hz, then what will be the new KVA rating?

1853


it is possible to measurement of tension of slipring induction motor(SRIM)carbon brushes, any maesuring instruments are available in the markets.

2077


what is the usage of microcontroller in the panel board?

2137


why are installed water leakage detection system data centers & server rooms

2462


Saving in copper achieved by converting a 2 winding transformer in to an auto transformer is determined by A voltage transformation ratio B load on secondary C quality of core material D size of transformer core

3237


What are merits & De-merits of State-Space Method? What is series programming, parallel programming, general programming & direct programming ? And, difference between these programmings Techniques ?

2466


When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<

2201


working principle a.v.r. ?

2487


how to calculate short circuit current for the busbar

1570


1. Why is the speed of shunt motor practically constant? 2. Why dc series motor use to start with heavy loads? 3. advantages & disadvantages of separately excited generator over self excited generator?

2594


is it value of power factor is more than unit. whats effects in the source supply

2122