Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

It is advisable 2 use auto-transformer if transformation
ratio is-a)110KV/11KV,b)230kv/110kv,c)110kv/66kv,d)
400kv/230kv

Answer Posted / k.prakashchandra

Yes,except a)

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

A 400KVA transformer has 400 Hz frequency. If the frequency is changed to 50 Hz, then what will be the new KVA rating?

1782


Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.

1584


When calculation of fault current and fault Kva is to be done,why always we use per unit value and why we consider the base kva?

1899


HOW TO CALCULATE CAPACITOR BANK OR HARMONIC FILTER CALCULATION

2304


What will happen if the voltage in my house drops from 220V to any lower voltage?

2192


what is meant by class 1 E in electrical power supply?

2096


how mass curve differs from hydrograph.

1776


Ac generato how produce power I need for camplet defination

1747


how can see the ac indoor or out door ac which Tr

2008


Explain the iniluencc of short circuit ratio on the pert'orniancc of synchronous machine.

2198


How Load Factor, Demand Factor, Diversity Factor etc best applied in designing an electrical circuit? Is it allowed to consider these factors in each and every panel in an electrical distribution system? Can any body suggest a good book for reference?

2887


what is meant by motor startup supervision & motor load jam protection ?

6005


What is Traction? 1KVA Alternator, How much urrent taken?

2113


how maney type tempereture measurement ?

2254


11 kg trivevter meter has rating of -/5amps. And pt ratio11000/110v and is connected with 11kv ct/pt unit of cr ratio 75/5amps. And pt ratio of 11000/110v while checking accuracy of meter with HT Accuchek meter what value of PT ratio and CT ratio to be filled in Accuchek meter