Answer Posted / ankur shrivastav
According to IRC 21:2000, clause 304.6.2----
Development/Lap Length is depends upon various factor--
like-
1. Grade of Concrete
2. Grade of Steel
3. Bonding Zone
Lap Length will be- nx Dia
Value of n is as below-
M20 M25 M30 M35 M40 and above
Fe500 66 56 48 42 42
Fe415 55 46 40 35 35
Fe 240 65 60 55 50 50
These values belongs only for bonding zone-1*.
For Bonding zone 2- n=1.4 x value of "n" in bonding zone 1
* Bonding Zone 2- Bonding Zone 2 is a zone where bar has been bent less than 45 degree angle and more than 300 mm fresh concrete is casted below the bars.
All other locations are bonding zone 1
Is This Answer Correct ? | 4 Yes | 1 No |
Post New Answer View All Answers
what are the code used for residental building?
how many type of admixtures for water stored structure?
What is an ortho mode?
what is the minimum reinforcement provided in beams,footings,slabs? what is the minimum soil bearing capacity to design a multistorey building
Please tell me Detail cost of providing& laying nominal mix design 1:2.5:5,40mm nominal size.curing complete e/c cost of form work in foundation and plinth i/c carriage.
Dear Sir, I work in hydro project. I want to hire Scorpio/ Bolero on monthly basis. But how can i justified its amount (Hourly basic). Please solve my problem
Explain what are the problems one might face while having a Cantilever balcony?
Can rice husk ash be used instead of coal fly ash for manufacture of clc/ foam concrete
What is limit state method and working stress method and ultimate method
what is E
How do we calculate absolute pressure?
What is quantity of cement and sand required for 2000sqft of tiling?
Different sizes of Hollow blocks and its weight. Thanks.
What is Joule Brayton Cycle?
Stringer How many cm goes to landind