Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what are the documentation and instrument identification system used to identify the correct device to be calibrated? name atleast three.

Answer Posted / carl_ellis

- P&ID: tag name/number for the instrument in question,
but not the location

- Loop diagram shows tag name/number, has a location
description (field, panel, I/O rack, control room) and
wiring terminals ID (are wires 1578 and 1579 connected to
the instrument in question?)

- ISA's instrument spec sheet has a section for calibration
with input/output, but more importantly, the following
section has Component Identification by manufacturer and
model number. The serial number isn't there because this
document defines the functionality, not a specific device.

- The company's "Instrument Specification Data Form" should
have a field for a location and instrument serial number

- Calibration data sheet should have a field
for "Location", tag and serial number.

- There should be a stainless tag on a field instrument

- The handheld communicator displays the tag name when
connected. The instrument's tag name should match the work
order's tag.

- The local "Calibration status label" on or inside the
instrument always has a tag ID.

Carl Ellis
Measure First

Is This Answer Correct ?    7 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

List three types Level Gauges with their working principles

2093


how to control pid

1919


why we should maintain neutral earth voltage below 1V while calibration? why cant it be 1.2V or 2V

2451


Specify eight technical requirements that you would consider important, when deciding upon a particular control valve?

1894


How to calibrate an pressure gauge with yantrika test bench?

2914


1. For Steam drum level signal, why do we compensate with drum pressure signal? 2.For main steam Flow signal is comensated with main steam temperature signal and main steam pressure signal why?

2235


Specify ideal accuracy of flow element like orifice plate, Ventury, Annubar. Ultrasonic flow meter etc.

1922


what would be the minimum flow rate that we can measure on rotameter..?

2103


What is the principle of capacitance type level transmitter?

1087


please send the sample qustion paper for iocl written test ..

3720


Why flow/pressure transmitter before control valve?

1579


i have been asked by QAFCO to appear for interview for thy post of Instrument Designer(INTOOLS)..i m engineering graduate with 5 years exp. in design engineering.Will this job profile suit me??i need all ur help n suggestions for thy same?

2236


what is the imbustion control loop

1891


what is function of switch, and how is it work, explain with difination

2382


Instrumentation Safe Guarding test. How to determine the interval time of the test. eg:Halfyearly,Every year,Every three years etc.

2124