Whats a difference between Verification Point and
Syncronization point?
Answer Posted / radha
Verification point is used for to check the application or
application functionality against expected results.
Synchronization point is used for to instruct Winrunner to
wait for a certain response from the application during a
test run.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
How do you handle tsl exceptions?
How do you copy and move objects between different gui map files?
What are the reasons that winrunner fails to identify gui object?
When do you feel you need to modify the logical name?
What is tsl? What 4gl is it similar too?
What are data driven tests?
Are there any suitable free tools to conduct performance test on a php web application?Manual or automation which is preferable for such kind of application? please answer ASAP
What are the different modes of recording in winrunner?
What is the purpose of regexp_msw_class property?
i get error "winrruner cannot identify object" and gives details like the physical description of object "windowsFor....378734a_11" has changed descritpion in GUI map new discription Description { { class:object class:object Msw_id:264896 Msw_id:918548 } } Below is a script of functionality where amount is transfered from users account ,first contact summary of user is opened then transfer button is available on which we click .on clicking transfer form opens and various details are entered like amount to be transfer,transfer type .line where i m getting error is obj_mouse_click ("WindowsForms10.Window.8.app have marked it with red in script .0.378734a", 164, 10, i would be very thankful if anyone can give help related to this problem. *SCRIPT IS BELOW:-* > # Shell_TrayWnd > set_window ("Shell_TrayWnd", 1); > toolbar_button_press ("ToolbarWindow32_1", "Contact summary - > Scheme: > SCHEME CARD PROGRAM (admin - Local - V.1.8.2.0000)"); # Button Number > 3; > > # Contact summary - Scheme: SCHEME CARD PROGRAM (admin - Local - > V.1.8.2.0000) > set_window ("Contact summary - Scheme: SCHEME CARD PROGRAM (admin - > Local - V.1.8.2.0000)", 1); > obj_mouse_click ("CommandBar1", 437, 15, LEFT); > > # Transfer (admin - Local - V.1.8.2.0000) > set_window ("Transfer (admin - Local - V.1.8.2.0000)", 1); > obj_mouse_click ("WindowsForms10.Window.8.app.0.378734a", 164, 10, > LEFT); > > # #32769 > set_window ("#32769", 0); > obj_mouse_click ("WindowsForms10.Window.8.app.0.378734a_0", 138, 9, > LEFT); > > # Transfer (admin - Local - V.1.8.2.0000) > set_window ("Transfer (admin - Local - V.1.8.2.0000)", 0); > obj_mouse_click ("WindowsForms10.Window.8.app.0.378734a_1", 166, > 13, LEFT); >
Difference between winrunner and test director?
Why don’t we normally load the gui maps through start up scripts?
How to do text matching?
How to check property of specific icon is highlighted or not?
How should we write and execute a user define function using WinRunner.