where they are using surge arrester and lighting arrester?
how they connect? what is the purpose of that?
Answer Posted / gopal agarwal
SURGE arresters are used for arresting i.e. controling
lightining surgs which are accured during clouding.these
lightining surges are of very high voltage ranges such as
many times greater than the rating of equipments ,which will
damage them and hence these are used at both sides end of
electrical equipments for protection.
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
(1)WHAT HAPPENS WHEN SUDDENLY LOAD GIVEN TO THE INDUCTION MOTOR ? (2)CAN WE MAKE WOOD AS MAGNET ? (3)WHAT IS THE VALUE OF MAGNETIC FLUX DENSITY IN TRANSFORMER ? (4)WHY WE ARE USING ELECTROMAGNETI NOT ELECTROSTATIC IN MACHINE ?
How to confirm the Phase shifting Transformer VECTOR GROUP relation , as below ZNy11.45d10.45-ZNYy0.15d11.15
how we can calculate power factor in single phase & three phase ?thank u
I need bhel previous year quetion papers for electrical engineering department.I searched but i could not find out
What is the vector group of a transformer,how can it be found out?
How can we choose the rating of submersible motors
Why derating factor os applied on Cables?
i need the curve duty cycle and amper for (150 kva @50% dyty cycle) transformer turn ratio :19 and vin 400
how rectifier transformer work in electroststic precipetatore(esp?
single phase power supply give to separate one steel coup with water, what reaction create
HOW DO YOU CAN CHECK A 15KV DIODE, WHETHER IT IS OK OR NOT?
we have two generators different capacity on 15 MW and other 6MW at 11 KV , 15 MW gen. bus short level current 40KA,and 6MW short level current 25KA,, length of cable 100MTR between 6 MW from 15MW gen. for bus coupling . kindly tell any one can we use both NGR OR one NGR from any GEN. BOTH NGR has diff. rating. Tariq pakistan
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
What is the Surge suppresor? Why using in a UDB's and How it works?
What does Bode plot tell you?