Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the difference between earthing,ground&nutral?

Answer Posted / surendhar

All electrical Circuits have ground point (the reference
point). It may be earth grounding (where reference point
connected to earth) or Chasis grounding (reference point
connected to chasis as in aircraft, car etc) or Floating
ground(where the reference point is not connected
anywhere).
Earthing, where the equipment case is connected to the
earth, to protect the equipment and the people who come in
contact with faulty conditions (Metal case of the equipment
coming in contact with the line).
If neutral is not present (floating neutral), then there
would be significant rise in the voltage at the neutral
point in the star connection (at the load end), because of
unbalancement in all three phases (practical case). This in
turn would affect the equipments connected across each
phase. So Neutral wire connects the neutral point at the
load end and the transformer end, where it would be
grounded. This causes current to flow in the neutral under
unbalanced situation, back to the transfomer, negating the
rise in voltage @ neutral point in load end.

Is This Answer Correct ?    1 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

can u describe the method used for protection of transmission line.

2225


PLS MENTION QUESTIONS ASKED IN IOCL INTERVIEW FOR ELECTRICAL EGG??

2426


Why do we need interlocking in a HT metering or Ring main unit switchgear?

2029


how to meas-our losses for L.T & H.T

2170


how to find the voltage's of a transmission line plzz help with pictures i am not able to understand

1365


what is is the potential diffrence between two phase ?

6440


Hi Suppose we have a wye/wye transformer which is grounded at both sides,in this situation, do we have ay ground transformer? in other words, ground transformer can do any thing more (while we have nuetral wire in both sides)? As the last question, what about 3rd harmonic? we have two choices: first using wye/delta transformer + ground transformer and second using wye/wye earthed connection.in the former choice, we dont have 3rd harmoonic at the secondary side but what about Yn/yn conection? do we suffer from 3rd harmonic in the Yn/yn connection?

1971


A 2083kva AVR was tested, phase to ground shows continuity, what is the implications

1033


do we use neutral grounding for resistive balanced load? if we use what happen?

1796


What is transient response?

1141


How can we calculate cable size in Low voltage & high voltage

1617


How eddy current generation support the idea of train braking?

2003


Dg pf .71 i am improve pf 0.80 what capacitor connected in dg how?

1683


please suggest some good universities with low cost iam in totally full confusion so please help me my profile gre 283 and ielts 5.5

1604


why 15 kw motor winding resistance is low then 5 kw motor winding resistance?

2836