Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

which motor is suitable for traction? why?

Answer Posted / hemlata

Series wound dc motor due to it has low resistance field and armature winding (according to ohms low I=V/R) advantage high current magnetic field inside the motor strong,produce high torque (turning force)

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

In parallel operation time both NGR’s close or not close if both close what will happen

3729


IF TVM OF TRANSFORMER SHOWS POWER FACTOR ON 33 KV SIDE AS 0.97 LAGGING AND ON 132 KV SIDE IS 0.75 LEADING.IS THIS CORRECT.WHERE IS PROBLEM.

2358


For overhead protection we use which transformer?

2482


What are the advantages & disadvantages of a group electrive drive?

2141


What will be the impact on motor performance if a LT motor is rewound with changed motor winding data as given below:- Original winding data: total 04 wires = 02 wires of 17 SWG + 02 wires of 16.5 SWG. Changed Winding data: total 03 wires of 15.5 SWG wire size Motor rating: 160KW, 740RPM, 415V, ID FAN application. Normal Running Current = 95% of FL Current.

2031


Vaccum circuit breaker

1386


what is the role and fuction of automatic transfer switch in rotary ups

1928


i want wipro vlsi placement pattern please send me

1766


Why let through energy not considered for ACB breaker while cable sizing?

2400


how to calculate sizing of NGTR (Transformer rating,Loading resistor value and Current rating of resistor) and what is the X/R ratio. Details : 11kV,Capacitance 1.73532 micro farads,40kA for 1sec.

2263


what is smart grid? why we use it? explain in detals bcoz i want give presentatin from it....

1937


How many double suspension hardware fittings are required on a double circuit transmission tower?

2100


Can u tell me design of switch yard

2165


How to decide DO set rating of Transformer?

1649


Difference between megger test equipment and contact resistance meter test instruments?

1319