Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

For a 500 MVA 400/220/33KV transformer following data given
HV power = 500 MVA
IV power = 500 MVA
LV power = 5 MVA
If input power is 500 MVA then how output power is
(500+5)MVA.
Can anyone help

Answer Posted / 7anoter4

If the tertiary winding is connected in Delta only in order
to cancel the current unbalance in steady state no current
will flow through it, that means no power consuming. See
[for instance]:http://www.electrical4u.com/tertiary-winding-
of-transformer-three-winding-transformer/

Is This Answer Correct ?    1 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why can the rotor of 3 phase slip ring induction motor not be a 2 phase rotor?

2107


I am using submission of two ct in one and half scheme for 67/67N protection. Both CTs star point is grounded separately near ct box.Will two point ground give wrong tripping to 67/67N during fault or no matter.

2156


Two liquids hot and cold in two vessels are there and an metal bar acts as a conductor of heat between the two vessels. what happens then. what happens after 24 hrs?

2250


11 kg trivevter meter has rating of -/5amps. And pt ratio11000/110v and is connected with 11kv ct/pt unit of cr ratio 75/5amps. And pt ratio of 11000/110v while checking accuracy of meter with HT Accuchek meter what value of PT ratio and CT ratio to be filled in Accuchek meter

1988


A parallel flow heat exchanger will perform better than a counter flow heat exchanger. State if the statement is true or false.

1318


Are Refrigerators & Deep Freezers the Inductive load ? How to calculate the Power Factor & hence the Output Power for them ?

5157


In between UPS out going changer over switch and ups raising main input, both side cable gland producing heat but the cable doesn't get heat,Why?

2332


pls tell what are doing the three phase motor star and delta connetion with circuit diagram and control wiring .

2052


direction of tarbine& genrator

2133


why swityard is necessrry requirement in any bis power distributin systems?

2434


what is the use of current transformer in power transformer secondary side.?its connectyed in WTI

1788


What is the restart inhabit setting in ABB spam150c relay (Motor protection relay)

3706


In single phase ac ups supply when current is measured with tong tester neutral current is found more than phase current.What is the reason?

2171


battery capacity use of made?

2597


What is pd controller?

1168