what is the difference between concentrated winding and
Distributed winding in motor?
Answer Posted / engineer aamir ali
A winding with only one slot per pole per phase is called a
concentrated winding. In this type of winding, the e.m.f
generated/phase is equal to the arithmetic sum of the
individual coil e.m.f.s in that phase. However, if the
coils/phase are distributed over several slots in space,
this kind of winding is called distributed winding. The
e.m.f.s in this case are not in phase but are displaced from
each other by the slot angle. the e.m.f will be the phasor
sum of the coil e.m.f.s.
REFERENCE: Principles of Electrical Machines By V.K Mehta
Is This Answer Correct ? | 33 Yes | 2 No |
Post New Answer View All Answers
we have two motors 1250kW,6.6kV to be coupled on the same shaft ,so please provide assistance for their synchronisation.
what is earth fault relay 64T, why it is used in main Incomer and neutral CT of Transformer.
what is sevice settings for mccb?How can be it setted?
please send me the L&T Emb. sys. placement papers and entire details of pattren
On a 3 winding transformer YNynd11, how do you apply REF protection to the Delta tertiary winding that is supplying auxiliaries to a substation?
what is class of SPD and dittels of all class ?
why you don not show protection and type of isolation in key single line diagram?
What is the distance between body earthing and neutral earthing.?
PLZ EXPLIN ABOUT CLASS PS CLASS CT .WHY THEY R DESINED AND FOR WHAT PURPOSE?WHY OTHER CT CANT BE USED AS PS CLASS CT? EXPLAIN IN SIMPLE LAUNGAGE IF POSSIBLE PLZ GIVE CIRCIT DIAGRAM?EMAIL-RAJ_SINGH_0376@SIFY.COM
What is the formuala to calculate the rating of motor protection circuit breaker
wat system call?
1.why we are using metal oxide gapless block in lightning arrester,2.What is minimum and maximum rating of metal oxide blocks using in india
what may the reason for vector shift in a generator?
what is the difference between ac motor and dc generator
Why a Permanent Magnet Generator has higher frequency as compared to frequency of main alternator?