what are the possible reasons if a control valve fails to open/close?
Answer Posted / carl_ellis
I seen 10 to 20 causes for each of these categories, but
I've only listed one as an example.
Reasons for valve not closing or opening:
intentional or unintentional
- lack of energy - air/electric/hydraulic (Fuse blown)
- insufficient energy - (supply air regulator turned down)
- control system issue (control signal interlocked)
- positioner or I/P issue (locked in manual)
- actuator crippled (punctured diaphragm)
- positioner-to-actuator linkage/plumbing issue (tubing failed)
- actuator-to-valve linkage issue (sheared roll pin)
- valve trim damage
- foreign object blocking movement (how does all that junk
get in the piping in the first place?)
- change in design process conditions (actuator can't close
against increased line pressure)
Not all failures to actuate/move are faults - a valve could
be intentionally locked in place for safety reasons - access
to the piping/tank.
Tell 'em Carl sent you.
| Is This Answer Correct ? | 15 Yes | 0 No |
Post New Answer View All Answers
installation process of orifice,a question asked for confusion creation in interview by BARC 1.if orifice is tightly fitted with pipe ,it will act like venturi 2.if orifice is left hanging in between liquid it will not create the pressure difference exactly,
Isometric drawings are generated during _________________ phase of a project
how to calibrate Necleuonic level transmitter.?
Sir , i have completed my M.Sc In Instrumentation and presently working in Maintenance department 3 yrs Exp , is there is any possible for work in offshore ..
what is IEC code in cables & how to selecting cables?
How r the calculation of process line mpm.
How you calibrate absolute pressure with the calibration range of 0 to 1000 0C Absolute. Please explain the procedure for calibration.
What is force balance principle?
I want measure the volumetric flow of gas in waste heat recovery Boiler?Tell me how and which type of instruments required. Plz mail me:naba02222@gmail.com Sam please post the answer .
Regarding , there is an air cooler which control the fans(50% of AV FANS) by temperature in outlet , and the louver of Air cooler is controlled by HIC from control system , So if on Air cooler we will consider 2 individual I/P converter or positioner?
what will the sending unit in the fuel gauge utilizes?
need to calculate flow rate with the help of dp range and orifice bore dia and size. range is 0 to 400 inwc and orifice size is 12 inch 150 # rf and bore dia is 7.180 inch. need to calculation for flow rate
how do calibrate the valves.. with clear manual
IN CONTROL VALVE SPECIFICATIONS GENERALLY TERM " DE- 200" ."DM -400"USED,, WHAT IS DE/ DM STANDS FOR?
What is the meaning of wet leg