What is meant by Anchorage length? Development Length?
Answer Posted / alehegn yehuala
Basically the development length is the length which should
be such that the stress should develop on both sides of the
point of maximum stress in the steel bar. If this point is
in the mid span of the beam then it can develop on both
sides but if the maximum stress is at the end (like in
cantilever) then we need to provide extra length beyond the
end support center line. If this extra anchoring length is
straight which is not beyond the nominal cover of the end
support then its same as development length and if this
extra anchoring is beyond the nominal cover of the end
support, then it is not straight bar i.e. with hooks then it
is called as anchorage length which is used to provide full
development length & an additional length for stability of
the structure.Therefore it is the anchorage length must
provide to detail any structure which have the same
situation as described in the above rather than development
length.
| Is This Answer Correct ? | 31 Yes | 6 No |
Post New Answer View All Answers
how many time use of plywood shuttering and IS code
How to calculate the force on a column of three story building. What should be the base concrete height?.
Need help in designing a degasser tower for 2m3/hr DM plant, also send me the formulae used
What is the difference between yeild strength and compressive strength of steel???
what happening if we casting HV shunt reactor foundation pad at 50cm height different time (One day difference)
what is moment-curvature relationship in semi rigid connections??
1) write Short notes about Shellow & Deep well? 2) What is the full form of SPT & SMB? write short notes. 3) write short notes about efficiency of Riveted joint.
what quantities of work done in terms of sq.mts/day/ of 8hrs for each varpenter (shuttering) and Steel fitter in terms of Tonnes. For slabs, Columns etc.?
what might be the problem faced in the near future if the M-sand is used in the place of river sand during wall plastering? (As per IS)
water leak detection system question & answer
how much of the strength comes from post-production curing
how to calculate the density for high density concrete ? or is it same as the density of RC?
IS STEEL BARS IS AS PER ISI TRANSVERSE RIBS SHOULD BE UNIFORM IN DISTANCE, PLEASE EXPLAIN WHY,
where will be the reinforcement of slab placed when there is an inverted beam and the bottom of the beam and slab are at same level ?
what is high type road and low type roads