Q- Which of the following is Close loop system -
a-)respiratory System b-)traffic light system c-)washing
machine d-)Room heater
my option is A, what is our take on option B & C
Answer Posted / carl_ellis
A room heater has a thermostat which senses room
temperature and turns the heater elements on or off, as
needed. It is close loop control.
A washing machine can have a closed loop feedback loop, for
example, water level, where a knob sets water level desired
[setpoint], a sensor detects level and turns off water
valve when satisfied. But the overall wash, soak, rinse,
empty, fill, spin functions are sequenced on a timed basis,
which is classic, open loop, non-feedback control.
Likewise a traffic light system can sense the presence of a
vehicle at an intersection, which enables an upcoming light
change, but the sequences of light changes are timer based,
open loop, non-feedback control.
Carl Ellis
Measure First
| Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
Why do you want to work here
hi,i am doing 3 year in electronic and instrumentation engineering. what type of aptitude questions will be asked in a core industries and how can i improve my skills in instrumentation?
How process line mpm calculation is done?
How can test or measure the probe and extension cable to identify if the problem at the probe or cable or at the driver it self? (pleast notify the measuring method)
HOW CREATED LP & HP PRESURES IN DRUM FOR DRUM LEVEL MEASUREMENT!
How to Calibrate Radar Level Transmitter in Field
How to calibrate radar type level transmitter for interface level? Total liquid(liq.1 and liq.2), level both the liq individually? For. Both the liquid levels how the signal will go from transmitter to dcs? How to calibrate. Single radar 9:26:55 AM for 2 different liquids in a tank?
if my flow is 20000 m3/h than which range of DPT i have to use????
If i have 4 Allen Bradely make RS logix 5000 PLC and for viewing that we are using 4 RS view SCADA for 4 different packages. Now, I will want to view two packages on only one SCADA. Then how i will do it?
what is the importance of CV in the control valves? how it is calculated?
selection criteria of control valve? and selection criteria of actuator explain in brief?
what is loop1 and loop2 in MTS LT?
is motorized valve closed when power shutoff?
we are using centum vp as monitoring with Dell precision work station T3600 but some times PC(s) are restarted automatically . how we can solve this problem? thanks
Explain an adaptive / self-tuning controller’s major draw card.