Coriolis flow meter coil supply is 24vdc but why still we given 230ac for this transmitter let me explained detailed review please
Answer Posted / uddipan sarkar
first of all mass flow transmitters are 4-wire tx. In 4-
wire tx we give a seperate source to power up the Tx and
from its ma terminal we take the 4-20 ma current signal.its
not a loop powered transmitter like the 2 wire.
you should first clear ur concepts about 2-wire tx and 4-
wire tx
| Is This Answer Correct ? | 1 Yes | 3 No |
Post New Answer View All Answers
Why use ball valves on Gas pipelines instead of gate & or globe valves...means basic diffrence or use of these valves..how designers knows this type of valve with rating is required...
we have a s-5 simense plc having op7 .recently on op7 showing error 1.plc not present 2. DB error frequently. can u have any solution . please send me.
what is zero and span ?
in differential pressure transmitter,min&max pressure range for hp&lp
pls provide me syllabus and old question paper of instrumentation engineering for GET(JSPL)
Drum level tx with GP4 with zero elevation:7300mmh20 on HP and 8050mmh2o on LP as range but on commissioning the tx readiing is max,Why this reading?
There are many type of control cable like pair,core,tried, What are defination each one
what is the criteria to decide conductor size of a cable ?
With N nodes and B branches what will have a network ???
(1) In turbine, what does term CDP, NI, NH, HSSOC, means. (2) What is the purpose of LO overhead tank in turbines.(3) An equipment is certified for EEX, IA, IIC,T6, what do you under stand by this.(4) what is SURGE, and how it is prevented, what is the purpose of bypass valve across AS valve.(5) Give 2 application of quartz crystal used for process parameter measurement.(6) what is meant by cold float of compressor shaft. (7) state four different types of flow measurement. For gas flow measurement mmscfd is the common unit. Expand the unit and specify significance of word S in the unit.(8) what is meant by Gap voltage, in vibration measurement. Normally how much Gap voltage is set and state the reason.(9) what will the new flow factor if D/P transmitter is Re-Ranged from 25” wc to 50” wc.(10) what is the usage of QDV & Volume booster.
I am using 971 Enraf radar level transmitter for LPG tanks ,the tank side indicator gives the error code 999999999FL can any body give me any diagnostic for this issue?
how to calculate orifice sizing? and tell me if pipe size bet 50mm t0 200mm then we can use pipe flange??? and above 250mm pipe size should i use D & D/2 Flange? is it right or wrong?
how pressurize drum calibrated ?
What is the meaning of wet leg
What is the purpose of the analyzer in petrochemical plant?