why neutral is required in electrical system
Answer Posted / rvd.chakkara
For return path, as well as for single phase supply.
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
in parallel operation of power transformer why the distance between power transformer and capacitor bank feeder is necessary to know
why transformer ratings in kva? & DG ratings in kva? & Motor ratings in kw/HP?
on a three-winding transformer relationship delta-delta-star, on third winding why the relationship is a star? what are the advantages and disadvantages? Thank you and please help
how to calculate the earth fault current
I am shobana from Chennai. I am having my personal interview on 19th Dec at Chennai.kindly mail me the questions to mail id shobana.shanthi@gmail.com
What is the difference between single point and double point bonding. please kindly detail about bonding of cables.
What is the basic of DTH.
How much pf maintan in dg set in 6o% load,when Dg runnig Neutaal Earthing removed what happen.
Can we indroduce the principle of single phase induction mator to Transformer? i.e. by Producing rotating flux in the transformer.
need to make a report. Need to choose a 3phase induction motor. Load conditions motor will operate in : Maximum Load: 30 Kw Speed: 2950 rpm Ambient temp: 20 cent Supply voltage: 440V Frequency: 50Hz need to look for the safety factor when choosing the motor, went through catalouge found a few, but dont know how to choose the safety factor allowing an extra load something above 30 KW to avoid any harm.
I Just want do EHS Certified Certification Distance Course From Govt approved,so can any body provide me details.
kindly send me 11KV MV motor differential protection procedure by primary injection method.
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
we are having 15kw and 3kw motor both can run in same time , instead of using copper we are using ug aluminium cable , 35 sq.mm is suitable for its current carrying capacity..?
Why current shoots up in the secondary on the knee point voltage during saturation test of CT? How core saturation effects the secondary current (while the primary side is open)? What the logic behind this?