What is different between hypo test and megger test
Answer Posted / s.j.shukla
Hypo test is HIGH VOLTAGE test according to voltage rating under test. Say for 415 V , AT 2KV /4KV as per customer requirement & for 11 KV , 28 KV OR SO..bASICALLY IT IS ACTUALLY HIGH VOLTAGE TEST. However meggering is a measurement of DC equivelent insulation resistance of any insulation.
| Is This Answer Correct ? | 8 Yes | 1 No |
Post New Answer View All Answers
Please provided formula for calculate the cable size from step up transformer to M.V panel, run overhead aluminum cables, total load is 5mega watt, total length 900 feet.
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
What is the permissable nutral current of three phase system as per IS standards?
why cable i burning without tripping. how can protect led street lights
What will happen if the d.c. Machine is operated below rated speed?
In Power Line Communication (PLC) the wave trap is used to block communication signals from entering neighboring lines. My question is this: Why do they allow for different filtering arrangements on these wave traps? Isn't it always going to be a low pass filter since we want the power frequency to go through, and the comm signal blocked?
how is working bearing heater?
Why neutral is not used in three phases dol starter
A 3-phase IM is supplied from 50 Hz system. It runs at speed of 1440 rpm and slip equal to 4 %. Calculate number of pole pairs. A 1 B 6 C 2 D 3
wow to calculate the transformer rating(KVA)
Why the dc voltage drop during starting of emergency lube oil pump? The Voltage drop from 135kv to 125 kv for one min. before re-establish to 135kv?
what is difference between cpp electrical system and refinery electrical system
An ELHNC 80amp 240v 30mA RCD is tripping periodically, every 30 - 180 seconds is it safe to disconnect the protection circuit?
WRITEDOWN FEW RELY CODES
what is high - pot test. what's its use?????