Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why the transformers are rating in KVA.?

Answer Posted / panda171


Power given to the transformer is Apparent power (K)
it is the supply power of the power house and the power
given by the transformer to the Load is the true power or
Active power which is actual used by the load and rest is
the reactive power i.e. square of apparent power including
iron loss & copper loss in KVA = square of true power in KW
+ square of reactive power in KVAR. A sound transformer
efficiency is 98% (input power- Iron loss (k) & copper loss
= output power).
For full resistive load (at unity pf ) a 100 KVA
transformer gives 100 KW (approx.) true power, and for
inductive power at .8 pf the same will able to give 80 KW
(approx.) true power, but the types of load (its pf) is not
know before which to be connected across the transformer,
this is only why the transformers are rated in KVA and it
is meaningless to discuss about the iron loss and copper
loss because the Inventor and UPS are also rated in
KVA.

In other hand or in simply we can
say due to unknowing power factor the transformer,
generator etc are rated in KVA. In heavy size transformer
copper loss is more and it vary with load and Climate
i.e. transformer oil condition but it is not reason to
rating the transformer in KVA.


P.C. Panda (BRG)
Mob 9938431756

Is This Answer Correct ?    7 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Enlists the applications of sampled data systems?

1092


In PFI plant one stage capacitor connection is directly connected(with out megnetic contact controll). but why?

2296


What is resonant peak?

1108


What is advantages of VSCF wind electrical system?

2334


Can you any one explain application of buccholz relay operation and pressure relif device operation of power transformer

1864


why u r living from presentaly working.

2578


1 Ton is equal to how many watts?

1105


what is Fan Control Cubicle

2487


hi friends i m from electrical branch and seeking for tech. + apti. both papers of hpcl plz get it available as soon as possible

1849


We need to current density & short circuit calculation at 65kA for aluminium & copper busbar.

1747


What is the main purpose of c.f.b.c.boiler

1723


Why HT 11 KV Slipring Motors are connected in star ?

2226


Please sent me some previous year question papers of BSNL-JTO telecom and RRB in ELectrical Engineering to varshashahi@yahoo.com

2069


Explain with example of functional requirements of protection relay in terms reliability, selectivity, sensitivity

1891


What is power distribution criteria for converting single phase unbalanced residential load to 3 phase star connected balance system. Does total KW converted to 3 Phase. Means Divided by root 3.

2336