Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What it the purpose of parallel phasing transfomers??

Answer Posted / ravishankar singh

To parallel them with 200MW//50MW.
Same princpal is every where in india
and across the world of inter collection

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

i am an maintenance engineer. one distribution board have 5 feeder. recently its ELR trips frequently, but it take some times after trip( 10min,20min..)but 3 feeder no load. two feeder only loaded. i checked one feeder IR value all values are above 50Mohm.but B phase to Earth is only 9Mohm.any problem about low value

1949


What are the different types of hydro schemes?

1273


How much pf maintan in dg set in 6o% load,when Dg runnig Neutaal Earthing removed what happen.

1973


what is transient stability analysis means?

2147


whats the application of voltage regulation? and whats the voltage regulation's device?

1898


how we decide scurt (disc) of insulator with respect to kv rating

3569


Is it acceptable of installing an earth pit in planters area where bare copper cable, earth rod and connection are susceptible to corrosion due to water?

1961


we have 3.5MVA-11/6KV transformer. how can we calculate earth fault current and NGR calculation?

1538


define the active power?

2017


How will you justify IR value and Charging voltage of any motor,transformer and Cables.......???? . . . . . . . . Plz tell me any body Baljeet Singh, engineer_89@refiff.com

2122


How to check the Bushings of the transformer?

1815


What are the weight of 800KV DA,DB and DC type tower ?

3146


for 100 HP Induction motor service factor is 1.2(SF) we placed a VFD at the motor side load is balance with 0.3 Amp's Phase to Phase but at incoming of VFD load is un-balance with 10 to 20 Amp's what will be cause of load un balance

1946


why industry prefer ht motor instead of lt motor.

2129


SUTIABLE FOR ohm's law super conductor