Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what diff. between
earth nd neutral?

Answer Posted / antu paul ekkan joseph

The value of potential(volts) for a balanced polyphase(eg. 3 phase system) is zero volts.But for unbalanced polyphase system the value depends on relative phase shift angle between phases.For single phase system neutral is the normal return path for the load current.But earth is supposed accidental bypassing path for the fault currents(eg. shortckt. current,leakage current,etc. etc..)It might be might not be a p.d b/w neutral and earth depends on the type of distribution system (single phase or poly phase),type of earthing system ie, TN,TNCS,TNS,IT,TT and its connections.

Is This Answer Correct ?    6 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

where are the circulat the diesel in DG parts name with pictue

2138


What is measurement?

1189


What is the de rating factor of cable? What is the importance of the de rating factor in cable select

2387


what is the main difference between power devices and signal devices

2191


sir vizag steel ka junior trainee ka paper kitne number ka ayega

2247


Can we use Ccapacitive voltage transformer directly for metering purpose?

1863


Hi My dear all Friends, There is a question regarding HVAC Engineering and widely used in Power Projects. Question- What is the diffrence Between REF, SEF and Differential Protection....???? Where REF - Restricted Earth Fault SEF - Senstive Earth Fault.

2183


what is consequences of neutral and earth connect?

2124


An impedance of 100 ohms resistance and an unknown inductance is connected across the capacitor. The resulting impedance is a pure resistance of 500 ohms ifω = 10^5 rad/sec. calculate the values of inductor and capacitor.

1424


How to set a Zone 1 distance relay for distribution feeder?

2028


what is deffrence between squirral cage and wound rotor in IM?

1971


whether fibre optic cable in high voltage earth conductor is used for protection circuits

1614


Why does inductive loads consume KVARs?

2075


can we start slipring motor on star delta like we start induction motor ? if yes where will we connect ?

1962


Compare jfet’s and mosfet’s.

1284