Name some application zrea where IDMT relay can used?
Answer Posted / manikandan
Yes, IDMT means Inverse definite Minimum Time, that means
the relay tripping time decreases when the fault current of
the system increases.this relay mainly used for Distribution
feeder, transformer, AC machines protection and over load
protection of AC power system.
Is This Answer Correct ? | 7 Yes | 1 No |
Post New Answer View All Answers
what is the eight bit unit?
Some times to change of DOR of a motor, interchange of R & B is not effected and RYB take same current, but interchange of R&Y is effected ie change the DOR. My doubt is what is the problem in motor and how it is happen.
Hi, Next week Iam appearing RRB exam for section engineer. So help me to get modal question papers for this position. Iam very thankful to you. Whether question will be fully techanical format or general form. Please give me a details regarding this exam.
ASTM D 3455 - Standard Test Methods for Compatibility of Construction Material with Electrical Insulating Oil of Petroleum Origin has been used for Testing Transformer Oils with a product placed in it. Aged Control Oil has a Power Factor of 0.032% at 100°C. Aged Oil with a Test component has a Power Factor of 0.093% at 100°. Is this increase acceptable? If not why? How much increase is acceptable?
sir, Is their any measuring unit of knoking? please explian?
what would u consider to be the basic purchase order information you would need to proceed with a cable inspection assignment?
how to calculate the change over time for star delta starter for different KW motor?
Explain difference between stand by earth fault and residual earth fault protection?
I have motor of 3 H.P. How i found the rating of capacitor use in it in single phase motor..???
If I want to connect a capacitor bank on the HT side of a 11kV/415V, 3 phase delta-star distribution transformer to supply Reactive power to it..what practical specifications of a Capacitor bank that can i've??please reply..
how generator avr give to the input?
What is miller crystal oscillator? Explain its operation?
I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?
how do we calculate length of starting time and repeated starting of a direct online starter?
what is meant by motor startup supervision & motor load jam protection ?