Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why the transformers are rated in KVA. ? in new view.

Answer Posted / pradyumna171


Power given to the transformer is Apparent power (K)
it is the supply power of the power house and the power
given by the transformer to the Load is the true power or
Active power which is actual used by the load and rest is
the reactive power i.e. square of apparent power including
iron loss & copper loss in KVA = square of true power in KW
+ square of reactive power in KVAR. A sound transformer
efficiency is 98% (input power- Iron loss (k) & copper loss
= output power).
For full resistive load (at unity pf ) a 100 KVA
transformer gives 100 KW (approx.) true power, and for
inductive power at .8 pf the same will able to give 80 KW
(approx.) true power, but the types of load (its pf) is not
know before which to be connected across the transformer,
this is only why the transformers are rated in KVA and it
is meaningless to discuss about the iron loss and copper
loss because the Inventor and UPS are also rated in
KVA.

In other hand or in simply we can
say due to unknowing power factor the transformer,
generator etc are rated in KVA. In heavy size transformer
copper loss is more and it vary with load and Climate i.e.
transformer oil condition but it is not main reason for
rating the transformer in KVA.


Pradyumna Chandra Panda
Berhampur Mob 9861357949

Is This Answer Correct ?    10 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Is it required to lay GI wires along with GI/MS conduits from one point to another point though separate earthing cable is conncted from DB to Socket?

2050


what is earth-fault?when it occurs? to check where it occurs what type of test should we do?

2053


what will be the min and max voltage flow from neutral to earth?

1595


How many types of circuit loads are there in a common electrical circuit?

1203


Why the dc voltage drop during starting of emergency lube oil pump? The Voltage drop from 135kv to 125 kv for one min. before re-establish to 135kv?

2371


solar inverters was not connected to the nuteral link .this nutwral possible to any other systems

1927


Can 4pole (3 phase+neautral )RCCB proper functioning in only 3 phase load (no neautral, no Earth) ?

2199


how we can calculate chiller required ampear?

2114


sir please send me techinical questions for junior engineer posting in bangalore railway i am diploma holder

2142


What is the method to solve circuit using source transformation?

1191


What is vacuum circuit breaker.define with cause and where be use it device?

1374


while doing high voltage test on 11kv/433 distribution transformer why we only give 28 kv on hv side and 3kv on lv side for power transformers what is the value what factors it depends

2916


In which of the following case, the rotating magnetic field is reversed? A regenerative breaking B plugging C dynamic breaking D forward motoring

2012


What is the use of oil in transformers?

1162


sugest any typical project ?

1871