Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why we generate transmit and distribute electrical supply
in multiple of 11

Answer Posted / deepak panwar

Transformer induced voltage equation contains 4.44 factor, i.e. E= 4.44*f*T*Phi
E= induced emf/phase
T= no. of turns
f= frequency
Phi= maximum flux/ pole
Since, E is proportional to 4.44 and it is in turn multiple of 11. So always transmission and distribution voltage are multiple of 11.

Is This Answer Correct ?    2 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

HOE WE CAN IMPROOVE BY USE OF CAPACITOR

1958


Explain Circuit Breaker Trip Characteristics in detail.

2130


The Howland current source produces a A Unidirectional floating load current B Bidirectional single-ended load current C Unidirectional single-ended load current D Bidirectional floating load current

2080


How PSV sizing being done

2314


how do you test tachos and servos

2112


How short circuit MVA(Fault MVA) in a power system calculated for calculating number of earth plates ?

2290


Differentiate between Zero and Negative sequence current

1895


How to calculate multiplying factor of dc energy meter

1664


i am in need of AC SYNCHRONUS MOTOR 30KW. ANY ONE KNOWS THE MANUFACTURER OF SAME. ALSO MOSFET AC CONVERTER 20KVA CONT.OUTPUT.

1920


Why derivative controller is not used in control systems?

1172


bsec exam syllabus (mis)

1273


if there are six generators (3 gas CATT, one Jenbacher o1 MW each, and two nos Diesel 01 no 01 mw other 0.65mw EDGs ( say), 3 CAtt gas set have identical pole pitch,01mw EDG and Jenbacher gas Set have different pole pitch, how their power connection can be done to connect a common bus bar during installation. in short, how different pole pitched generators power connection can be done to connect a common busbar system through generators incomer ACBs.

1592


Dear All we are having a problem in G120 BOP showing alarm A0503, F0052, F0060 we can not remove fault alarm ,Please any body help us. kowsar

1811


anyone please send transformer parameter design formulas & details of tap changer ? plz i have interview this week its more helpful for me ?

1857


How to connect the chemical earthing and complete process tell me plz

1855