Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

WHAT IS THE LIQUID PHASE IN DB-624 COLUMN IN GCHS

Answer Posted / palabindela

DR-624 is a Low-Medium polarity 3.5% Cyanopropyl, 3.5%
Phenyl 93% Methyl polysiloxane phase

Is This Answer Correct ?    3 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is lod and loq ?,why use k2cr2o7 , kcl h2so4 in uv calibration ?,why use benzophenone & caffene acetone in hplc calibration ?,what is leading peak in hplc ?why we do the calibration of limit of stry light in hplc & uv ?

3660


As per ICH related substances stability trend limit from initial to shelf life

3242


How do we get end points and how many end points are possible for citric acid and di-acid not theorotically answer should be given practically.

2580


In which situation we require to prepare the standard solution from sample in Related substance method?

769


How to establish relative response factor for hplc. Why it is required?

1215


can we use the same detector in HPLC as well GC and what could be the differences we can find in the final chromato graph in any aspects?

2175


what is mean by nitrosamine impurities?

1058


I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3532


why cone formation during dissolution?

775


what you do when compound having dwel wavelength?

738


What is split ratio in Gc? Splitless? how requirr to select?

872


how you establish the LOQ?

780


what is classification of elemental impurities? what is risk assement in elemental impurities?

752


How can we confirm the HPLC column is end-capped or not? Is it possible to identify by physical appearance?

3207


why require to do water content for drug product?

822