why the generating voltage in India is 11kV or why is it be
transmitted as multiples of 11
Answer Posted / siddhesh mhatre
reason is something historical: in olden days when the electricity became popular, engineers had a misconception that there would be a voltage loss of around 10% in the transmission line. So, in order to get 10 kilovolts at the load point, they started sending 11 kilovolts from supply side. This is the reason. It has nothing to do with form factor (1.11).
Nowadays that thought has changed and we are using 400 V instead of 440 V, or 230 V instead of 220 V.
| Is This Answer Correct ? | 1 Yes | 1 No |
Post New Answer View All Answers
how to calculate IR value of 33KV cable ??
How to decide whether A / B / C / D curve type MCB should be used?
To make a basic instrumentation amplifier, it takes A One op-amp with a certain feedback arrangement B Two op-amp and seven resistors C Three op-amps and seven capacitors D Three op-amps and seven resistors
Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.
what are the precuation should be taken ahen installing power transformer,circuit breaker,current & potential transformer
We have studied about many techniques for finding the stability of system, ROOT LOCUS, ROUTH, BODE PLOT, POLER PLOT etc. In these which is used where. what are the difference among them... PLZ tell me.......
where rlc series ckt used?
WHY IS THE EARTH FAULT CURRENT ALWAYS LESS THAN THE NORMAL CURRENT??
What is given by the definition in BIL IMP/PF = 950/395 kV. This was found in a name plate of a power transformer.
How is the percentage impedence of a transformer fixed at design stage???
why using transformer and thyristor switch in 3 phase apfc panel
i have some screw comprressor with 630kw power,i have established them with simple star to delta circuit,by the way there is so much inertia when the screw comprressors start, can you offer me contactors power with 400vac or any cataluge to choose the contactors
In between UPS out going changer over switch and ups raising main input, both side cable gland producing heat but the cable doesn't get heat,Why?
how to get electrical supervisour certificate in gujarat
How to run a three phase motor into single phase........